https://appliancetechmanuals.com
7-8 Communication Error (CO E)
No
Check for loose connection in CON101 from
1
PCB Display.
2
Check voltage between wires Red to Blue.
CON101
Check voltage between wires Blue to Yellow.
3
CON101
Check voltage between wires Blue to Purple.
4
CON101
1.- Check for loose connection in CON5
5
from Main PCB.
2.- Check voltage between wires Blue to
Yellow.
<Drawer Model>
<Swing Model>
Checking flow
<CON101>
<Display>
<CON101>
<Display>
<CON101>
<Display>
Result & SVC Action
Result
SVC Action
12 V
Go to the 3
Check the Hinge
Other
(loose connection)
Change the Main PCB
Result
SVC Action
0 V or 5 V
Change the Display PCB
Other
Go to the 4
Result
SVC Action
0 V or 5 V
Change the Main PCB
Other
Go to the 5
Result
SVC Action
0 V or 5 V
Change the Display PCB
Other
Go to the 6