Kenmore 795.71312.311 Service Manual page 36

Bottom freezer refrigerator
Table of Contents

Advertisement

https://appliancetechmanuals.com
10. COMPONENT TESTING INFORMATION
10-1 Defrost Controller Assembly
Function
- Controller assembly is consist of 2 kinds of part those are fuse-m and sensor. we can
- Fuse-m can cut off the source when defrost heater operate the unusual high temperature.
- Sensor give temperature information to Micom
How to
Measure
(Fuse-M)
How to
Measure
(Sensor)
Standard
decide part is defect or not when we check the resistance.
(1) to (2)
(1) to (2)
Fuse-M (at all temperature)
Test Point
(1) to (2)
0 ~ 0.1Ù
Set a ohmmeter to the 2 housing pin.
Measure the 2 pin connected to Fuse-M.
If the ohmmeter indicate below 0.1ohm
fuse-m is a good condition, But infinitely
great ohm Fuse-M is disconnection
Set a ohmmeter to The 2housing pin.
Measure the 2 pin connected to Sensor.
If the ohmmeter indicate 11㏀ (at room
temperature) Sensor is not a defect.
When check the ohm at other temperature
Check the sensor manual.
Sensor (at room temperature)
Ressult
Test Point
(1) to (2)
Ressult
11Ù

Advertisement

Table of Contents
loading

This manual is also suitable for:

795.71313.311795.71314.311795.71319.311

Table of Contents