Limitation of electricity consumption
If you do not have enough electricity and decide to turn the con-
sumption limiter on, you must configure the system software as in-
dicated (refer to the wiring diagrams to identify the type of electrical
box on board the hot tub).
Make sure the spa is disconnected from the power supply line.
Remove the cover of the electrical box and set the switch
("dip-switch") n ° 1 to the OFF position.
PROFILE "TOP"
In the OFF position, the electric heater switches off when a
whirlpool pump is activated.
PROFILE "BASE" (DSP)
In the OFF position, the electric heater switches off when the
whirlpool pump is activated in high speed.
NOTES
- When dipswitch 1 is set to ON, the maximum electrical consump-
tion is selected.
Check of operation
First start-up
Check that the filter cartridge is present in its container and
that the various components are properly installed (see the chap-
ter on maintenance of the filter cartridge).
ON
1
2
3
4
5
6
7
8
29
A
Check that the drain valve (V) on the base (and the ball valve
V1, if installed) are closed.
V1
Check that all the hydromassage intakes are open.
A
V