3. CONVERSION RULES FOR THE PROGRAM CONVERSION FUNCTION
Application instructions for F
Applicable model
*1
F
, F
F
1
1J
2
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
36
, F
, and F
1
1J
2
Instruction
number
*2
F670
New F
2
Addition between D and K with carry
Yes
K55
addition (3-digit BCD)
Addition between D and K with carry
Yes
K56
addition (6-digit BCD)
Addition between data registers
Yes
K57
(3-digit BCD)
Addition between data registers with
Yes
K58
carry addition (3-digit BCD)
Addition between data registers with
Yes
K59
carry addition (6-digit BCD)
Addition between data registers
Yes
K60
(3-digit OCT)
Data register increment
Yes
K61
(3-digit BCD)
Data register increment
Yes
K62
(6-digit BCD)
Data register increment
Yes
K63
(3-digit OCT)
Current counter value increment
Yes
K64
(3-digit BCD)
Current counter value increment
Yes
K65
(6-digit BCD)
Subtraction between D and K with
Yes
K66
borrow subtraction (3-digit BCD)
Subtraction between D and K with
Yes
K67
borrow subtraction (6-digit BCD)
Subtraction between data registers
Yes
K68
(3-digit BCD)
Subtraction between data registers
Yes
K69
with borrow subtraction
(3-digit BCD)
Subtraction between data registers
Yes
K70
with borrow subtraction
(6-digit BCD)
Subtraction between data registers
Yes
K71
(3-digit OCT)
Data register decrement
Yes
K72
(3-digit BCD)
Data register decrement
Yes
K73
(6-digit BCD)
Data register decrement
Yes
K74
(3-digit OCT)
Current counter value decrement
Yes
K75
(3-digit BCD)
*1 Generic term for F
earlier than V2.1
*2 Generic term for F
V2.1 or later
programmable controllers
Name
series running on versions
2
series running on version
2
Application instruction (FNC number) and
function of the FX programmable controller
to be changed
ADD (FNC 20)
ADD (FNC 20)
ADD (FNC 20)
ADD (FNC 20)
ADD (FNC 20)
ADD (FNC 20)
INC (FNC 24)
INC (FNC 24)
INC (FNC 24)
The corresponding FX series instruction is
a binary operation, so the numerical control
for the relevant program needs to be
changed from octal to binary (decimal).
INC (FNC 24)
INC (FNC 24)
SUB (FNC 21)
SUB (FNC 21)
SUB (FNC 21)
SUB (FNC 21)
SUB (FNC 21)
SUB (FNC 21)
DEC (FNC 25)
DEC (FNC 25)
DEC (FNC 25)
The corresponding FX series instruction is
a binary operation, so the numerical control
for the relevant program needs to be
changed from octal to binary (decimal).
DEC (FNC 25)