Technical data
9.1 Functional data
Variable
Temperature coefficient
Characteristic value T
Zero signal T
Min. initial loading E
Maximum working load L
Break load L
Maximum lateral load L
Rated measuring path h
Recommended supply voltage
Rated characteristic value C
Tolerance of zero signal D
Input resistance R
Output resistance R
Insulation resistance R
Rated temperature range B
Operating temperature range B
Storage temperature range B
Sensor material
Degree of protection according to EN 60 529
Cable connection
Output is current-calibrated
*
9.1.13

SIWAREX WL270 CP-S SB

Table 9-13
Variable
Type series
Designation
Construction type
Possible applications
Rated load E
Accuracy class according to OIML R60
Max. scale interval n
Min. scale interval V
Combined error F
Deviation F
Creep error F
30 min
62
Kc
Ko
min
u
d
lq
at E
n
max
Rated
o
i
o
is
tn
tu
ts
Technical data SIWAREX WL270 CP-S SB
max
LC
min
comb
V
cr
Value
0.017% C
/ 10 K
n
0.023% C
/ 10 K
n
0 kg
150% E
max
300% E
max
75% E
max
0.5 mm
5 to 12 V DC
2.0 ± 0.02 mV/V
*
< ± 1.0% C
n
700 ± 7 Ω
700 ± 7 Ω
5000 MΩ at 50 V DC
- 10 ... + 40 °C
- 35 ... + 65 °C
- 35 ... + 65 °C
Stainless steel, mat. no. 1.4542
IP68
Four-core, shielded PU cable
15 m
Value
WL270
CP-S SB
Compression load cell
Container weighers
100 t
C3
3000
E
/ 9000
max
± 0.02% C
n
± 0.02% C
n
0.023% C
n
Operating Instructions, 12/2021, A5E02199611B-13