Damage To Load Cells, Measurement Errors; Specific Conditions Of Use - Siemens SIWAREX WL260 Series Operating Instructions Manual

Weighing systems. load cells.
Hide thumbs Also See for SIWAREX WL260 Series:
Table of Contents

Advertisement

Safety instructions

2.6 Specific conditions of use

2.5

Damage to load cells, measurement errors

NOTICE
Damage to load cells, measurement errors
Dirt must not be allowed to accumulate in the vicinity of a load cell.
Do not subject cable glands and seals to the jet from a pressure washer.
2.6
Specific conditions of use
1. Using the box provided on the nameplate, the User shall permanently mark the type of
protection chosen for the specific installation. Once the type of protection has been marked
it shall not be changed.
Ex ia IIIC T73°C Da X
0 Ex ia IIC T4 Ga X
OC НАНИО «ЦСВЭ»
№ RU C–DE.BH02.B.00316/20
IS CL I,II,III, DIV 1, GP A,B,C,D,E,F,G,T4
IS CL I, ZN 0, AEx/Ex ia IIC T4 Ga
CL I,II,III, DIV 2, GP A,B,C,D,F,G, T4
US & CA
CL I, ZN2, GP IIC T4
FM21US0086X
IS CL I, ZN 2, AEx/Ex ic IIC T4 Gc IP6X
FM21CA0056X
Install per Control Drawing A5E51333396A
Figure 2-1
Nameplate example with box
2. The load cells do not have an earth ground terminal or conductor. The load cells shall be earth
grounded as part of the final installation.
3. The non-metallic surfaces on the Load Cell's enclosure may cause risk from electrostatic
discharge. Avoid installation that could cause electrostatic build-up, and only clean with a
damp cloth.
Note
The resistance between all safety ground connections and the system grounding electrode shall
not exceed 1 ohm.
Note
The associated apparatus shall be a single entity-Approved/Certified associated apparatus device
with outputs that are Approved/Certified for parallel connection of field wiring within the
applicable hazardouslocation / explosive atmosphere Within the United States,the voltage and
current parameters of such associated apparatus are commonly identified using the parameters
Vt (voltage, total) and It (current, total) The use of multiple associated apparatus that are not
Approved/Certified for use in combination with one another as a system is only permitted as
specified below.
14
0518
2813
FM21UKEX0173X
FM21UKEX0174X
UK Importer :
Siemens plc, Manchester M20 2UK, UK
Refer to manual
FM09ATEX0040X / FM09ATEX0041X
II 1G Ex ia IIC T4 G a
II 1D Ex ia IIIC T
135°C Da
200
II 3G Ex ic IIC T4 Gc
For the US-Zone 20, AEx ia IIIC T135°C Da
For Canada-Ex ia IIIC T 135°C D a
A5E34794967A-2014X
II 3G Ex nA IIC T4 Gc
II 3D Ex tc IIIC T73°C Dc
-20°C ≤ Ta ≤ +40°C