    INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. GENERAL INDEX INTRODUCTION ..........................3 INSTALACIÓN SAM ......................... 3 MOUNTING ............................3 3.1. MOUNTING AND LOCATION OF TX80 ................3 3.2. MOUNTING AND LOCATION OF SKYGLASS ..............4 ELECTRICAL INSTALLATION ....................... 5 SEALING ............................11 5.1.
  • Page 3: Introduction

    INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. 1. INTRODUCTION This document describes the installation and parameterization of the taximeter TAXITRONIC TX80 SKYGLASS. 2. INSTALACIÓN SAM To introduce SAM card the device must be opened, then introduce SAM card in the skyglass groove as there is shown on the plane To configure the SAM card, the toolkit manual (SIM/SAM configuration section) indications must be followed.
  • Page 4: Mounting And Location Of Skyglass

    INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. TX80 must be installed so that passengers can’t see or access it. Seals and serial numbers must be easily visible and accessible upon verification at a verification office. For this reason it is necessary to take care of the orientation, with the stickers looking to the outside.
  • Page 5: Electrical Installation

    INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. 4. ELECTRICAL INSTALLATION To access the TX80 connectors it is necessary to open the Connector cover Take out the screw that seals the cover Connect each cable into its connector Pass each cable through its retention...
  • Page 6 INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. • (4) Serial Port Contact number Function + 12 V + 5 V RS232 levels +- 12V TTTL levels 0 - 5 V Ground • (5) CAN Accessories Contact number Color Function + 12V...
  • Page 7 INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. TX80 CONNECTORS IPL80 connection IPL80 must be connected to CAN accessories (5) connector. The rooflight cables must be connected to IPL80 as the rooflight installation diagram shows. Inst TX80_Skyglass_003_en.doc...
  • Page 8 INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. COMPLETE INSTALLATION Inst TX80_Skyglass_003_en.doc...
  • Page 9 INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. Parallel rooflight installation Inst TX80_Skyglass_003_en.doc...
  • Page 10 INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. INSTALLATION IN A VEHICLE WITH CIA447 PROTOCOL Inst TX80_Skyglass_003_en.doc...
  • Page 11: Sealing

    INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. RECOMMENDATIONS FOR THE ELECTRICAL INSTALLATION − Disconnect the positive terminal on the battery until the whole electrical installation is completed. − Any manipulation of the taximeter or of the external lights must be done while the taximeter is disconnected from the power supply −...
  • Page 12: Skyglass Sealing

    If you need this kind of seal, the taximeter kit should include an antiturn angle and screws with a hole for the cables 6. TECHNICAL CHARACTERISTICS The general technical characteristics of TX80 SKYGLASS are as follows: − Power supply voltage Nominal = 12 V...
  • Page 13 INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. − Maximum consumption taximeter off = 6 mA − Maximum consumption inside battery = 2.5 A − Maximum power 36 W for each external light of 60 W in case that 3 outputs are connected in parallel.
  • Page 14: Impulse Generator

    INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. 7. IMPULSE GENERATOR 7.1. INTRODUCTION − For the vehicles with mechanical speedometer, you have to use a pulse generator that is managed by the taximeter. − The pulse generator is inserted in the cable of the speedometer and converts the mechanical movement of this cable in an electrical signal, which is amplified and filtered by the taximeter.
  • Page 15 INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. − Finally all pieces are assembled by screwing together the two fixing rings taking into account that the separating space indicated by (8) must be sufficient. Inst TX80_Skyglass_003_en.doc...
  • Page 16: Cable Connection, Cover Closing And Pulse Generator Support

    INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. 7.2.2. CABLE CONNECTION, COVER CLOSING AND PULSE GENERATOR SUPPORT − To connect the pulse generator cable it is necessary to open the pulse generator cover (item 1) after taking the closing screw out and moving the cover in the right direction indicated by the arrow.
  • Page 17: Sealing (Drawing 11)

    INSTALLATION MANUAL TX80 SKYGLASS INTERFACOM, S.A.U. 7.3. SEALING (Drawing 11) − The pulse generator installation can also be sealed, as shown in the image. 7.4. TECHNICAL CHARACTERISTICS − The main technical characteristics of the pulse generator are: − Sensor type: Hall effect cell −...

Table of Contents