INSTALLATION MANUAL TX80 SKYGLASS
4. ELECTRICAL INSTALLATION
To access the TX80 connectors it is necessary to open the Connector cover
Take out the screw that seals the cover
-
-
Connect each cable into its connector
Pass each cable through its retention
-
-
Break the holes in the top cover in order the cables can pass
Clos the device
-
-
Screw the cover
The TX80 has the following connectors:
• (1) CAN Vehicle
Contact number
Function
1
+ 12V
2
+ 5V
3
CAN H
4
CAN L
5
1
6
Ground
• (2) Power Supply
Contact number
Color
1
-
2
Green / White
3
-
4
-
5
-
6
Brown
7
Violet
8
Blue
9
Yellow
10
Green
12
Red
12
Red
13
Black
14
Black
* If the emergency signal is not used, Brown cable must be connected to ground.
• (3) Impulse Generator
Contact number
Color
1
Mesh
2
Red
3
Green
4
-
Inst TX80_Skyglass_003_en.doc
Function
-
Distance pulses
L4
L3
L2
Emergency signal
Passenger sensor
Contact Key
Position lights
Rooflight (L1)
Battery 12V
Battery 12V
Ground
Ground
Function
Ground
+ 5V
Signal
-
INTERFACOM, S.A.U.