1.2. Typical installation The Profino Revolution Lite can be used to provide high quality TV signals in a wide range of projects, both in the hospitality as in the residential market. Typical buildings or infrastructures where the Profino Revolution Lite can be used include, but are not limited to: •...
15 cm around the product to guarantee a maximum ventilation of the product • Connect an earth wire to the grounding clamp • Connect the inputs to the Profino Revolution Lite • Connect a coaxial cable to the output connector for distribution of the signal •...
Configuring the Profino Revolution Lite AVIGATING THROUGH THE MENU Use the Johansson rotary/push button to navigate through the menu. This is very straightforward and simple. The table below shows how the rotary/push should be used: Push the button 2s to enter the basic configuration.
Page 6
PROFINO REVOLUTION LITE (REF. 6714) Push the rotary button for 2 seconds to access the menu CHANNEL SCAN DISPLAY READOUT EXPLANATION Tap the rotary button to enter the channel scan menu Scroll down to START and tap the rotary button to...
Page 7
PROFINO REVOLUTION LITE (REF. 6714) INPUT SETTINGS DISPLAY READOUT EXPLANATION Tap INPUT V/U 1 to enter the menu to configure input Rotate the rotary button to scroll down in the submenu of INPUT V/U 1. PRE-AMPLI: The internal amplifier is by default ON,...
Page 8
PROFINO REVOLUTION LITE (REF. 6714) DISPLAY READOUT EXPLANATION To add another (group of) channel(s), scroll down to ADD CHANNEL and tap to confirm. To prevent bad quality or scrambled images, make sure that only one input channel is assigned to one output channel.
Page 9
PROFINO REVOLUTION LITE (REF. 6714) OUTPUT SETTINGS DISPLAY READOUT EXPLANATION Define the OUTPUT LEVEL of the output signal. Range between 88 dBµV and 108 dBµV (default output level is 98 dBµV). Note: The more channels you select, the less input power you should give (e.g.
Page 10
PROFINO REVOLUTION LITE (REF. 6714) ADVANCED SETTINGS DISPLAY READOUT EXPLANATION language of the Profiler Revolution can be set to English, Italian, Spanish or French. Tap REGION to check to which region/country the Profiler Revolution is set. To change the region/country, a hard reset is required (see instructions above (cfr.
Page 11
PROFINO REVOLUTION LITE (REF. 6714) EXIT SETTINGS DISPLAY READOUT EXPLANATION To avoid unauthorized people changing the settings, all Profiler products can be locked with a security code. Select LOCK and SET LOCK CODE. When the lock code is set, the device will shut down.