PDP67 F 8DI ION PT
}
Decentralised periphery
Operating Manual-1004253-EN-02

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PDP67 F 8DI ION PT and is the answer not in the manual?

Questions and answers

Summary of Contents for Pilz PDP67 F 8DI ION PT

  • Page 1 PDP67 F 8DI ION PT Decentralised periphery Operating Manual-1004253-EN-02...
  • Page 2 Preface This document is the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for the user's internal purposes. Suggestions and comments for improving this documenta- tion will be gratefully received.
  • Page 3: Table Of Contents

    Example: Single-channel, failsafe input device, with test pulse 6.3.4 Example: Dual-channel, failsafe input device, with test pulse Section 7 Operation Messages Section 8 Technical details Safety characteristic data Section 9 Order reference Product Accessories Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 4: Operating Manual Pdp67 F 8Di Ion Pt

    Introduction Introduction Validity of documentation This documentation is valid for the product PDP67 F 8DI ION PT. It is valid until new docu- mentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product.
  • Page 5 Introduction INFORMATION This gives advice on applications and provides information on special fea- tures. Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 6: Overview

    Unit features Application of the product PDP67 F 8DI ION PT: Decentralised input module for connection to a Pilz control system, for use in a rugged in- dustrial environment up to protection type IP67. The product has the following features:...
  • Page 7: Front View

    Inputs and outputs Interface to the control system or to X6 on the upstream module Interface to X5 on the downstream module LEDs: – Device – Fault – Traffic – IO0 ... IO7 Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 8: Safety

    Safety Intended use The product PDP67 F 8DI ION PT is a decentralised input module which is suitable for use in a rugged industrial environment up to protection type IP67. The module can be connected to a PDP link module PNOZ ml2p, PNOZ mml2p or PNOZ m EF PDP Link from the configurable control system PNOZmulti.
  • Page 9: Disposal

    In safety-related applications, please comply with the mission time T in the safety-re- lated characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 10: Function Description

    Communication with the control system is via a safe data link. Data is exchanged cyclically. Diagnostics The status and error messages shown by the LEDs are saved in an error stack. The sys- tem software can read this error stack. Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 11: Installation

    Fit 2 x M4 internal threads on the mounting surface. Use two fixing screws to attach the product to the mounting plate. With shielded cables, connect the functional earth to a screw on X0. Dimensions Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 12: Wiring

    Please refer to the link module's operating manual for details of the maximum cable length. Pilz pre-assembled cable can be used to connect the inputs and outputs (see order ref- erence). We recommend you use pre-assembled Pilz connectors to connect the inputs and test pulse outputs (see order reference).
  • Page 13: Connector Pin Assignment

    2: CAN- A-coded 3: GND 4: CAN+ 5: Shield Interface to the next decentralised module: X6 Assignment 5-pin M12 female 1: VCC connector 2: CAN- A-coded 3: GND 4: CAN+ 5: Shield Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 14: Wiring Examples

    – Appropriate wiring – Wiring in accordance with the requirements of IEC 61076-2-101 and IEC 60204-1, clause 14.1.1 and 14.1.2 Single-channel, failsafe sensor Fig.: Please ensure safety regulations and EMC guidelines are met! Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 15: Example: Dual-Channel Input Devices, Without Test Pulses

    – Wiring in accordance with the requirements of IEC 61076-2-101 and IEC 60204-1, clause 14.1.1 and 14.1.2 Dual-channel sensor with different (diverse) channels 24 V 24 V Fig.: Please ensure safety regulations and EMC guidelines are met! Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 16: Example: Single-Channel, Failsafe Input Device, With Test Pulse

    – Wiring in accordance with the requirements of IEC 61076-2-101 and IEC 60204-1, clause 14.1.1 and 14.1.2 Single-channel, failsafe sensor Test pulse T0 Fig.: Please ensure safety regulations and EMC guidelines are met! Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 17: Example: Dual-Channel, Failsafe Input Device, With Test Pulse

    Single-channel, failsafe sensor Test pulse T1 Test pulse T0 Test pulse T1 Test pulse T0 Fig.: Please ensure safety regulations and EMC guidelines are met! Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 18: Operation

    Green Link module has detected a pulse error. Once the fault has been rectified, the decentralised input module will continue to work normally after a waiting period of just a few seconds. 0 signal is present Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 19: Technical Details

    Typ. output current at "1" signal and rated voltage of semiconductor output 0,5 A Permitted current range 0,000 - 0,600 A Residual current at "0" signal 0,02 mA Max. internal voltage drop 200 mV Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 20 Airgap creepage In accordance with the standard IEC 60664-1 Overvoltage category Pollution degree Protection type In accordance with the standard EN 60529 Housing IP67 In accordance with UL Enclosure Type 1 Terminals IP67 Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 21: Safety Characteristic Data

    A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 22: Order Reference

    PSS67 Cable M12sf Cable, straight M12 connector, 10 m 380 210 M12sm straight M12 socket, 5-pin PSS67 Cable M12sf Cable, straight M12 connector, 30 m 380 211 M12sm straight M12 socket, 5-pin Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...
  • Page 23 380 308 PSS67 M12 connector Socket, M12, straight, 5-pin, A-coded 380 309 PSS67 M12 connector Connector, M12, angled, 5-pin, A-coded 380 310 PSS67 M12 connector Socket, M12, angled, 5-pin, A-coded 380 311 Operating Manual PDP67 F 8DI ION PT 1004253-EN-02...