Operating Instructions; Alarm Codes & Led Code Chart - Intex Krystal Clear Deluxe Owner's Manual

Table of Contents

Advertisement

(103CD) MODEL 8111 (MODEL 8110 + MODEL 51) DELUXE SALTWATER SYSTEM (SALT IN POOL) & FILTER PUMP ENGLISH 7.5" X 10.5" PANTONE 295U
No sanitizer production will occur if "Low Water Flow", "Low Salt Level" or "High Salt
Level" conditions are detected. If any of these conditions occur then the Saltwater
System will sound an alarm that indicates sanitizer production has stopped. A
buzzer will sound and a Code (see below) will keep flashing on the LED for 1 hour.
The buzzer and flashing light will stop after one hour and the Saltwater System will
go to Power Saving Mode. If this occurs then press any button (
the code of the original problem so that it can be corrected.
Turn off the power of the unit and follow the solutions below to solve the problem.
Turn on the unit again by following the "Operating Instructions".
Code
Low
Water
Flow or
No Flow
Low Salt
Level
High Salt
Level
• The expected life expectancy of the electrolytic cell is 3,000 hours under normal
use conditions.
• When replacing the cell, only use replacement cells having a label that clearly
states that it is a replacement cell for the
System (salt in pool) & Filter Pump Model
SAVE THESE INSTRUCTIONS
ALARM CODES
Cause
1. Circulation line
• Ensure the plunger valves are
opened (if any).
blocked.
• Ensure your filter cartridge, cell are
clear from debris and dirt. See
"Maintenance".
• Release all trapped air in the
circulation line. See Filter Pump
Manual.
• Check for the direction of water
2. Incorrect inlet and
inlet and water outlet hose. Reverse
outlet hose
the hoses if necessary. See "Set
direction.
Up Instructions".
• Ensure the flow sensor (especially
3. Scale on the flow
the hinge) is clean. See
sensor.
"Maintenance".
4. Flow sensor cord
• Check for flow sensor loose or not
connected properly. Plug the flow
is loose.
sensor firmly into the flow sensor
receptacle.
5. Flow sensor failure.
• Contact Intex Service Center for
replacement.
• Remove the electrolytic cell for
1. Dirt or scale on
titanium plates.
inspection and clean it if necessary.
See "Maintenance".
• Add salt. See "Salt & Pool Water
2. Low salt level / no
Volumes".
salt.
3. Possible electrolytic
• Contact Intex Service Center.
Replace the cell if needed.
cell failure.
1. High salt level.
• Partially drain the pool and refill
with fresh water. See "Salt & Pool
Water Volumes".
or
Remedy
Flashing Buzzer
Krystal Clear™ Deluxe Saltwater
8111.
12/25/2007
103
CD
) to view
Yes
Yes
Yes
Yes
Yes
Yes
Page 23