(103CD) MODEL 8111 (MODEL 8110 + MODEL 51) DELUXE SALTWATER SYSTEM (SALT IN POOL) & FILTER PUMP ENGLISH 7.5" X 10.5" PANTONE 295U
6. If flushing does not remove the deposits on the plate then disconnect the cell
from the base by removing the 2 mounting screws (10). Disconnect the flow
sensor from the top of the cell and unplug the electrolytic cell cord. Soak the
cell in a vinegar solution (condiment) for 2-3 hours and then flush with high
pressure water from the garden hose.
7. Reconnect electrolytic cell reversing steps 3, 4, 5 and 7. (Reset the Saltwater
System's operating hours)
NOTE: After cleaning the operating hours have to be reset.
It is recommended that the filter cartridge be replaced at least every 2 weeks.
1. Make sure the unit is turned off, and disconnect the power cord from the
electrical outlet.
2. Grasp a plunger valve handle. Turn the handle counter-clockwise, push down
until it stops and then turn it clockwise until the plastic protruding notch anchor
is in the "0/1" position. Repeat for the 2nd plunger valve. This prevents the water
from flowing out of the pool.
3. Gently turn both air release valves (1 & 7) 1-2 turns in a counter-clockwise
direction. This will allow the housing cover to be easily removed.
4. In a counter-clockwise direction remove the filter housing collar (3). Place it in a
safe location.
5. Remove the housing cover (4).
6. Remove the "OLD" filter cartridge.
7. Examine the inside of the filter housing.
8. If dirt or sediment is located on the bottom of the housing then:
A.
B.
C.
9. Place a new cartridge filter in the housing.
10.Return the housing cover (4) to its installed position and in a clockwise direction
rescrew the housing collar (3) onto the filter housing.
11. Turn both plunger valve handles in a counter-clockwise direction, pull up until
they stop, and then turn them clockwise until the metal protruding notch anchor
is in the "0/1" position.
12. Reconnect the power cord.
13. Turn the unit "ON".
14. When the trapped air has escaped through the air release valves gently
retighten the valves (1 & 7) in a clockwise direction.
SAVE THESE INSTRUCTIONS
VISUAL INSPECTION AND CLEANING (continued)
FILTER CARTRIDGE CLEANING OR REPLACEMENT
In a counter-clockwise motion gently unscrew and remove the sediment
valve (1) located at the bottom of the housing. Place it in a safe place.
With a bucket of water or a garden hose pour water into the housing
flushing out the sediment.
In a gentle clockwise motion return the sediment valve (1) to its installed
location. Do not over-tighten.