(103CD) MODEL 8111 (MODEL 8110 + MODEL 51) DELUXE SALTWATER SYSTEM (SALT IN POOL) & FILTER PUMP ENGLISH 7.5" X 10.5" PANTONE 295U
PROBLEM
AIR LOCK
INSUFFICIENT
SANITIZER
WHITE FLAKES IN
THE WATER
NO LED DISPLAY
If you continue to experience difficulty, please contact our Consumer
Service Department for assistance. See back cover for contact information.
SAVE THESE INSTRUCTIONS
TROUBLESHOOTING GUIDE (continued)
CAUSE
• Pump housing and inlet hose
air trapped.
• Inlet and outlet hoses
connection reversed.
• Insufficient operating hours of
the Saltwater System.
• Insufficient (Less than
2000ppm) salt level in pool
water.
• Sanitizer loss due to intense
sunlight exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• Excessive calcium hardness is
present in pool water.
• Power Saving Mode.
• No power supply.
• Electrolytic cell cord is loose.
• Power fuse blown.
• LED failure.
IMPORTANT
REMEDY
• Open air release valves, lift and lower
the inlet hose until water starts to flow
out of the air release valves, close air
release valves.
• Lower position of pool outlet connect to
filter pump water inlet, upper position
of pool inlet connect to filter pump
water outlet.
• Increase the Saltwater System
operating time per day. See "Operating
Instructions".
• Test the Salt Level with Test Kit, and
adjust as needed. See "Salt & Pool
Water Volumes".
• Use Pool Cover when the pool is not
use and/or when the unit is operating.
• Increase the Saltwater System
operating time per day. See "Operating
Instructions".
• Remove the cell for inspection, clean it
if necessary. See "Maintenance".
• Drain about 20 to 25% of the pool
water and add fresh water to decrease
the calcium hardness. Visually inspect
the electrolytic cell for scale build-up
and clean the electrolytic cell if
necessary.
• Press any button (
or
the last LED code.
• Check for power cord loose or not
connected properly.
• Check to see if cell cord is loose or not
connected properly. Ensure the cell
cord is plugged firmly into the cell
housing receptacle.
• Contact Intex Service Center for
replacement.
• Contact Intex Service Center for
replacement.