Vitodens 200-W B2HE 85, 120, 150, 199 Installation

Product Information

A Rating plate with access code for boiler registration

System Examples

Fittings and Sealing Points
Vitodens 200-W, type B2HE
Wall mounted gas condensing boiler with Inox-Radial
heat exchanger and the following integrated components:
Modulating MatrixPlus burner for natural gas or LPG
Hydraulics with 3-way diverter valve and variable
speed high efficiency circulation pump
Weather-compensated or constant temperature control
unit
DHW production
Vitodens 200-W boilers are for operation with natural gas.
For a fuel conversion to liquid propane gas refer to the
service instructions for details.
Boiler model must be selected based on an accurate heat
loss calculation of the building. Ensure boiler model is
compatible with connected radiation.
Vitodens 200-W, boilers are factory-tested and calibrated.
Further gas valve adjustments are not typically required
during field start-up.
The rating plate of the boiler contains extensive product
information and is boiler-specific. Access code with the
marking "i" for direct access to product-specific
information and product registration on the internet.
The access code contains the credentials for the
registration and product information portal, as well as the
16-digit serial number.
Note: A further label with the access code is enclosed
with the boiler.
Stick the label in the operating and service
instructions so it can be easily found again for
later use.
System examples with hydraulic and electrical connection
schemes and function descriptions are available to help
setting up the heating system, refer to the system layouts
starting on page 38.
All connections must be fitted with new gaskets after
opening or loosening.
WARNING
Risk of electric shock from escaping heating water or DHW.
When commissioning and after carrying out maintenance
work, check all water side connections for leaks.