GENERAL D'ASPIRAZIONE 126M Instructions For Installation, Use And Maintenance Manual page 32

Table of Contents

Advertisement

6.5
Non-routine maintenance
Extraordinary maintenance must be performed exclusively by authorised personnel.
The user can replace the remote panel battery by following the instructions below:
Inverter panel battery replacement
1.
Turn the cover on the back of the control panel anti-clockwise until it opens.
2.
Gently remove the battery.
3.
Replace with a new CR2032 battery. The battery holder has small retainers. First slide the battery in
on one side and then gently press down on the other side and the battery will snap in.
4.
Make sure that the positive pole of the battery is facing upwards.
5.
Replace the cover and tighten it down by turning it clockwise.
6.
Discard the old battery in compliance with local battery disposal laws.
The manufacturer does not authorize the user of the system to perform the remaining extraordinary
maintenance operations indicated below:
• Electronic programming
• Repairs / replacement of components
• Revisions
• Operational cycle changes
• Replacement of the power cable if damaged
it is necessary to send a request for intervention to the manufacturer's Technical Assistance Service
With the manufacturer's authorization, some operations can be performed by qualified personnel.
Periodic operations
Turbine maintenance
Inverter maintenance
Maintenance of self-cleaning compressor
Maintenance of self-cleaning tank
32
Normal frequency
10.000h
Every year
Every year
Not necessary