Use and Maintenance Manual
MONOBLOCK Vacuum Unit
4.3 Installation of the MONOBLOCK vacuum unit – 3 and 4 operators
The MONOBLOCK vacuum unit has been designed for easy and convenient installation.
The vacuum unit must be positioned respecting the clearance distances indicated in Figure 5. There must
be a space of 5 cm on each side of the vacuum unit, and a space of 25 cm to the rear.
In these installation conditions, the suction inlet is 78 cm above floor level and 25 cm from the wall. The air
expulsion outlet is 190 cm above the floor and also 25 cm from the rear wall. (see figure 6)
The MONOBLOCK vacuum unit must now be connected to the suction pipes of the system and to the air
expulsion pipe, using the rubber hoses with metallic fixing clamps provided.
IMPORTANT
●
point 80 metres.
●
after increase the diameter.
●
exhaust air.
Maximum distance from the Monoblock vacuum unit to the most distant suction
For the air expulsion pipe, the first seven metres must consist in Ø100 mm pipes,
Important: Connect the metal muffler to the Exhaust to reduce the noise of the