5.10 List of favourite parameters
The parameters in the favourites are divided into two groups:
User customisation parameters:
All the parameters highlighted in grey in the table belong to this list. They can be changed by the end user
without having to enter a password.
Central configuration parameters:
The remaining parameters (not highlighted in grey) are password-protected and need to be enabled for
modification. To change these parameters, enter the password "480" using parameter 96.02. After making
the change, enter password "14" using parameter 96.02 to lock the parameters again.
Parameter
Description
34_12
Timer 1
start time
40_21
Internal Set Point
31_04
Event type External Event 2
"Check Container"
"Check Container"
31_10
Event type External Event 5
"Check Filter"
"Check Filter"
47_04
Data Memory 4 real32
"Switch-off frequency for wireless
systems"
47_11
Data Memory 1 int32
"Switch-off delay for wireless systems"
47_12
Data Memory 2 int32
"Switch-off delay for Standard systems" 5 sec.
47_13
Data Memory 3 int32
"Check Container"
47_14
Data Memory 4 int32
"Check filter"
47_24
Data Memory 4 int16
"Operating Mode"
96_01
Language
96_02
Password
Default value
08:00:00 PM
-160mbar
Lowest setting value -100mbar
Highest setting value -200mbar
Warning (the inverter will trip the alarm but the
vacuum system will continue to operate)
By setting Fault in case of alarm the vacuum system
will be stopped
Warning (the inverter will trip the alarm but the
vacuum system will continue to operate)
By setting Fault in case of alarm the vacuum system
will be stopped
Varies according to the vacuum system model
30 sec.
1000 (set 1000 for a trip time at 100 hours)
3000 for a system without self-cleaning
5000 for a system with self-cleaning (set 2000 for a
trip time at 200 hours)
See "OPERATING PRINCIPLE DEFINITION" table at
section 5.9
Italian (unless customised otherwise)
480 (password to unlock all favourite parameters)