TABLE OF CONTENTS INTRODUCTION AND GENERAL NOTES ................. 4 INSTALLATION NOTES ..................... 4 USE AND MAINTENANCE NOTES ..................4 MAIN FEATURES ....................... 5 MACHINE KEYPAD ......................7 STARTING UP ........................7 DISPENSING ........................8 HOW TO MAKE A GOOD CUP OF COFFEE ..............9 DOSE PROGRAMMING ....................
INTRODUCTION AND GENERAL NOTES Thoroughly read the instructions contained in this booklet because it gives important information regarding safety for installation, use and maintenance. Keep this booklet in a safe and accessible place for further consultation. This machine must be used only for the purpose it was designed: dispensing coffee, cappuccino, pouring hot water.
MAIN FEATURES MACHINE 1 GR. 2 GR. Maximum quantity of coffee dispensed per hour Width (mm.) Height (mm.) Depth (mm.) Net weight (Kg.) Boiler capacity (lt.) Hot water nozzle Steam nozzle Automatic cappuccino LM maker optional Boiler resistor (W) Standard version 1600 2700 Voltage...
Page 6
ELECTRIC CONNECTION HYDRAULIC CONNECTION WATER WATER TAP DRAIN ( 1 – 5 BAR ) WATER FILTR WATER SOFTNER LB-00193-10-GB Pag. 6 10-02-09...
MACHINE KEYPAD KEY 1 KEY 2 KEY 3 KEY 4 KEY 5 Group keypad 1 Espresso Key 1 Key 2 2 Espressi 1 Coffee Key 3 2 Coffee Key 4 Key 5 Continue/Prog. STARTING UP Turn on the tap from the water mains and swi witch the power ON by pressing the “I.G “...
DISPENSING 1) Coffee Dispensing. Place a cup under the dispenser and press one of the coffee dose keys (N° 1-2-3-4 ). The dose will aut omatically stop once the pre-programmed dose has been delivered. The system can be used for the simultaneous dispensing of coffee from all the groups on the machine. The “5”...
HOW TO MAKE A GOOD CUP OF COFFEE The physical state of the ground coffee is fundamental for a good beverage. Condition of the coffee It comes out slowly It comes out rapidly Dose of ground coffee Excessive Insufficient Pressure on ground coffee Excessive Insufficient Atmospheric humidity...
DOSE PROGRAMMING The following procedure is the same for bo both 1 and 2 group versions. Please note that the display m y messages are shown just in the 2 group version, which is equipped wit with display. 1) Programming the volumetric coffee do dose .
" Where ON XXX ml. is the pre-infusion water quantity. Push T1 or T2 to scroll the menu and T5 to confirm Where OFF XXX Sec. is the pause between Pre-infusion and Infusion Push T1 or T2 to scroll the menu and T5 to confirm Please note: The pre-infusion works only on the first two key on each group keypads.
WASHING 1) Washing the group and filter holder. It is advisable to carry out these types of washing at the end of each working day. 1a) washing the filter holders. Carry out the following operations: Remove the filters from the filter holders and wash both parts under running water. Remove the remaining coffee using the provided brush ( code N°...
Page 13
MANUAL CLEANING OF STEAM WAND PLEASE NOTE: It is advisable to carry out these types of cleaning at the end of each working day 1► 2► Leave the steam wand into Clean the steam wand by hot water for 5 minutes. means of a cloth.
SPECIAL FUNCTIONS FOR MACHINE CALIBRATION Only Assistance Service personnel authorised by I.M.C. Spa. are permitted to enable the use of these functions. 1) Calibrating the coffee dispensing pressure ( pump pressure) To adjust the pump pressure insert the filter holder filled with properly ground, pressed coffee dose. Press a coffee dose key and read the pressure in the pressure gauge.
Page 15
Turbine alarm. Cause: the volume meter is not sending signals to the control unit within a time-out of 5 seconds. Result: delivery continues up to a time-out of 240 seconds or until the selected key is pressed, and all the leds on the push-button panels flash (medial flashes) The display shows: Solution: carry out the following controls.
Third case: the temperature probe is defective and send a 154 Ohm (open circuit) signal to the pc board. Effect: boiler heating is interrupted and drink keys are disabled. Solution: switch off the machine ( OFF ), replace the temperature probe and switch on the machine. Attention: Periodically check the electric wiring of the TRIAC.
Page 29
The I.M.C. S.p.A. product you have purchased is subject to Directive 2002/96/EC of the European Parliament and the Council of the European Union on waste electrical and electronic equipment (WEEE) and, in jurisdictions adopting that Directive, is marked as being put on the market after August 13, 2005, and should not be disposed of as unsorted municipal waste.
Need help?
Do you have a question about the PRATICA and is the answer not in the manual?