WP2 LED WEATHERPROOF LED BATTENS
1
2
NO ALTERATIONS WITHOUT DESIGN OFFICE APPROVAL
A
B
1
2
3
4
NO ALTERATIONS WITHOUT DESIGN OFFICE APPROVAL
A
C
B
D
C
E
D
F
Installation
E
G
■ Disconnect mains supply before installing, servicing or maintaining the luminaire.
F
H
■ Attach the stainless steel clips to the body of the luminaire and attach the row
of clips on one side of the luminaire to the diffuser (clip must be attached to the
G
I
protruding side of the diffuser).
■ The gear tray should be detached to assist with installation by twisting the quarter
H
K
turn fasteners.
1
2
I
■ Drill out mounting holes.
■ Use the supplied screw set to ensure IP65 is maintained.
K
■ Fit the power cable through the supplied IP65 gland.
1
2
3
4
■ Make the electrical connection at the terminal block:
N – Neutral
A – Active
E – Earth
■ For DALI models connect the data cable to the two terminals labelled "DA".
■ For Emergency models, an additional Switched Active terminal is provided
to allow the luminaire to be switched ON and OFF in mains mode.
For non-maintained operation, do not connect the switched active terminal.
■ For Galaxy models, see the illustration for the correct orientation of the
antenna.
■ Clip and secure the lanyards to the gear tray.
■ Secure the gear tray to the base.
■ Close the diffuser and ensure diffuser clips are locked in place..
Ceiling Mount (as supplied)
For wall mount the antenna bracket should be bend 90 degrees as shown (no need to undo the antenna).
Note: Antenna illustration is for Galaxy models.
3
4
5
6
7
5
6
7
8
9
(230.0 - MOUNTING HOLES)
(670.0)
(812.0 - MOUNTING HOLES)
(1275.0)
3
4
5
6
7
5
6
7
8
9
ANTENNA POSITION FOR 2FT BATTEN
8
9
10
11
12
10
11
12
13
14
(100.4)
8
9
10
11
12
2
1
Item Item Name
DO NOT SCALE
LIFECYCLE STATE
LEGRAND AUSTRALIA PTY. LTD. ALL
RIGHTS RESERVED. THIS DRAWING
MAY NOT BE REPRODUCED OR
Released
TRANSMITTED IN ANY FORM OR BY
ANY MEANS, IN PART OR IN WHOLE
WITHOUT THE WRITTEN PERMISSION
OF LEGRAND AUSTRALIA PTY. LTD.
GENERAL TOLERANCES UNLESS SPECIFIED
DESIGN
PRADEEP
27/05/2014
LINEAR
STEP SIZE
DESIGN REVIEW
melvinder singh
01 Jun 15
<3
>3 - 6incl
>6 - 30incl
PD REVIEW
Paul Barron
02 Jun 15
>30-120incl
>120
CTO REVIEW
Dennis Galvin
03 Jun 15
ANGULAR
MATERIAL
COATING
SCALE
THIRD ANGLE PROJECTION
0.50
SEE PARTS
SEE PARTS
FILE NAME ASSY_4FT_LED_GRP_AG05041AE
10
11
12
13
14
Wall Mount
13
14
15
16
REVISIONS "A" ORIGINAL ISSUE
REV.B PAN 150601
MAJOR MOD TO GEARTRAY
A
Specifications
All models
B
15
16
REVISIONS "A" ORIGINAL ISSUE
Supply Voltage
REV.B PAN 150601
MAJOR MOD TO GEARTRAY
A
C
Power Factor
Colour Temperature
B
D
IP Rating
(100.4)
C
E
D
F
E
G
F
H
G
I
2
SUB ASSY CASING
AG04781AB
1
1
SUB ASSY - GEARTRAY
AF04783AE
1
Item Item Name
Dwg/Art No
Qty
DO NOT SCALE
LIFECYCLE STATE
Tel 1300 369 777
Tel +61 2 8783 4333
LEGRAND AUSTRALIA PTY. LTD. ALL
RIGHTS RESERVED. THIS DRAWING
MAY NOT BE REPRODUCED OR
Released
Fax +61 2 8783 4470
TRANSMITTED IN ANY FORM OR BY
ANY MEANS, IN PART OR IN WHOLE
www.hpmlegrand.com.au
WITHOUT THE WRITTEN PERMISSION
OF LEGRAND AUSTRALIA PTY. LTD.
H
GENERAL TOLERANCES UNLESS SPECIFIED
DESIGN
PAN
01/08/2013
TITLE
LINEAR
2FT LED WP BATTEN
K
STEP SIZE
DESIGN REVIEW
melvinder singh
01 Jun 15
<3
>3 - 6incl
>6 - 30incl
PD REVIEW
Paul Barron
02 Jun 15
WITH GRP V3236F CASE
>30-120incl
>120
CTO REVIEW
Dennis Galvin
03 Jun 15
ANGULAR
MATERIAL
COATING
SCALE
SHEET
CAT NO.
FILE NO.
REVISION
THIRD ANGLE PROJECTION
AG05041AA
B.4
SEE PARTS
SEE PARTS
0.50
A1
TBA
FILE NAME ASSY_2FT_LED_GRP_AG05041AD
UNLESS OTHERWISE STATED ALL DIMENSIONS IN MM
SHEET 2 OF 2
13
14
15
16
I
SUB ASSY CASE
AG04781AC
1
SUB ASSY - GEARTRAY
AF04783AF
1
Dwg/Art No
Qty
Tel 1300 369 777
Tel +61 2 8783 4333
Fax +61 2 8783 4470
www.hpmlegrand.com.au
TITLE
4FT LED WP BATTEN
K
WITH GRP V3236F CASE
SHEET
CAT NO.
FILE NO.
REVISION
A1
TBA
AG05041AE
B.6
UNLESS OTHERWISE STATED ALL DIMENSIONS IN MM
SHEET 2 OF 2
15
16
Ceiling Mount (as supplied)
For wall mount undo the antenna and install
as shown.
ANTENNA POSITION FOR 4FT BATTEN
230 - 240 V a.c. 50 Hz
>0.9
4000 K
IP65
Wall Mount

Advertisement

loading
Need help?

Need help?

Do you have a question about the WP2 LED and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for LEGRAND WP2 LED

  • Page 1 WP2 LED WEATHERPROOF LED BATTENS NO ALTERATIONS WITHOUT DESIGN OFFICE APPROVAL REVISIONS "A" ORIGINAL ISSUE REV.B PAN 150601 MAJOR MOD TO GEARTRAY Specifications All models NO ALTERATIONS WITHOUT DESIGN OFFICE APPROVAL REVISIONS "A" ORIGINAL ISSUE Supply Voltage 230 - 240 V a.c. 50 Hz REV.B PAN 150601...
  • Page 2 2. This product must be installed by a licenced electrician. 3. Legrand reserves the right to modify the specifications of this product at any time. 4. This product should only be cleaned with a damp cloth. Cleaning agents and solvents should not be used.