# ISU
ISU Name
ISU Options (defaults in bold)
378
EM Heat CPH
1 - 12 CPH
(Heating cycle rate
Emergency Heat)
Off, 1 - 5 minutes
387
Compressor
Protection
390
Ext Fan Run Time
Off, 30, 60, 90 seconds
in Cool
2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 minutes
391
Ext Fan Run Time
Off, 30, 60, 90 seconds
in Heat
2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15 minutes
425
Adaptive Recovery
On, Off
429
Max Cool Temperature
from Min. Cool Temp. to 99 °F or to 37.0 °C (90 °F or 32 °C)
430
Min Cool Temperature
from 50 °F or 10.0 °C to Max. Cool Temp. (50 °F or 10 °C)
431
Max Heat Temperature
from Min. Heat Temp. to 90 °F or to 32.0 °C (90 °F or 32 °C)
432
Min Heat Temperature
from 40 °F or 4.4 °C to Max. Heat Temp. (50 °F or 10 °C)
500
Indoor Sensor
Yes, No
515
Sensor type
10k, 20k
520
Temperature Control
Thermostat, Wired, Average
702
Air Filters
0 - 2
711
Air Filter 1 Reminder
Off
10, 20, 30, 45, 60, 90, 120, 150 Run Time Days
30, 45, 60, 75 Days
3, 4, 5, 6, 9, 12, 15 Months
712
Air Filter 2 Reminder
Off
10, 20, 30, 45, 60, 90, 120, 150 Run Time Days
30, 45, 60, 75 Days
3, 4, 5, 6, 9, 12, 15 Months
Notes
This ISU is only displayed when Emergency Heat is configured and ISU 253: Aux/E Terminal Control is set to
control Aux and E heat Independently. The recommended cycle rate settings are below for each heating equip-
ment type:
Standard Efficiency Gas Forced Air = 5 CPH; High Efficiency Gas Forced Air =
3 CPH; Oil Forced Air = 5 CPH; Electric Forced Air = 9 CPH.
The thermostat has a built in compressor protection (minimum off timer) that prevents the compressor from
restarting too early after a shutdown. The minimum-off timer is activated after the compressor turns off. If
there is a call during the minimum-off timer, the thermostat shows "Wait" in the display. This ISU is displayed if
ISU 220 is set to at least 1 stage.
After the call for cooling ends, the thermostat keeps the fan on for the selected amount of time for increased
efficiency. This may reintroduce humidity into the living space. This ISU is displayed if ISU 220 is set to at least
1 stage.
After the call for heating ends, the thermostat keeps the fan on for the selected amount of time for increased
efficiency. This ISU is displayed if ISU 230 is set to Thermostat Controls Fan.
Adaptive Intelligent Recovery (AIR) is a comfort setting. Heating or cooling equipment will turn on earlier,
ensuring the indoor temperature will match the setpoint at the scheduled time.
The user cannot set the cooling temperature above this level.
The user cannot set the cooling temperature below this level.
The user cannot set the heating temperature above this level.
The user cannot set the heating temperature below this level.
Set this ISU when you want to wire a remote indoor sensor to the "S" terminals on the UWP - see "Wiring" on
page 6. This ISU is only displayed only if ISU 130 is set to NO wired outdoor sensor configured
Choose resistance type of wired indoor sensor. This ISU is only displayed when indoor sensor is configured -
ISU 500.
This ISU is only displayed when indoor sensor is configured - ISU 500. You can choose what temperature
source to be used or you can ask thermostat to use both thermostat and remote sensors for higher accuracy of
measurement.
This ISU refers to the number of air filters in the system.
Choose either calendar or equipment run time-based reminder.
Choose either calendar or equipment run time-based reminder.