T6 Pro Programmable
Thermostat
Installation Instructions
Package Includes:
• T6 Pro Thermostat
• UWP™ Mounting System
• Decorative Cover Plate
• Screws and Anchors
• 2 AA Batteries
• Thermostat Literature
Optional Cover Plate installation
NOTE: If Optional Cover Plate is not
required, see "UWP Mounting System
installation" on next page.
Use the Optional Cover Plate when
you need to cover paint gap from old
thermostat.
There are different cover plates
depending on when the thermostat was
manufactured.
For the square cover plate:
1. Separate the Cover Plate from
Mounting Plate.
2. Mount the Mounting Plate on to the
wall using any of the 8 screw holes.
Insert and tighten mounting screws
supplied with Cover Plate Kit. Do not
overtighten. See Figure 2. Make sure
the Mounting Plate is level.
3. Attach the UWP by hanging it on the
top hook of the Mounting Plate and
then snapping the bottom of the UWP
in place. See Figure 3.
4. Snap the Cover Plate onto the
Mounting Plate. See Figure 4.
TH6320U2008,
TH6220U2000,
TH6210U2001,
Read before installing
1
2
Use supplied
screws and
wall anchors
4
+
3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TH6320U2008 and is the answer not in the manual?

Questions and answers

Summary of Contents for Honeywell Home TH6320U2008

  • Page 1 T6 Pro Programmable Thermostat Installation Instructions – Package Includes: • T6 Pro Thermostat • UWP™ Mounting System • Decorative Cover Plate TH6320U2008, • Screws and Anchors TH6220U2000, • 2 AA Batteries TH6210U2001, • Thermostat Literature Read before installing Optional Cover Plate installation NOTE: If Optional Cover Plate is not required, see “UWP Mounting System...
  • Page 2 For the rectangular cover plate: 1. Mount the Cover Plate on the wall using any of the 6 screw holes. Insert and tighten the mounting screws supplied with the Cover Plate. Do not overtighten. See Figure 1. Make sure the Cover Plate is level. Attach the UWP by hanging it on the top hook of the Cover Plate and then snapping the bottom of the UWP in place.
  • Page 3: Power Options

    Power options Insert R and C wires into designated terminals Insert AA for primary AC power (C batteries for terminal is optional if primary or batteries are installed, backup power. but it is recommended). Remove wires by depressing the terminal tabs.
  • Page 4 Wiring conventional systems: forced air and hydronics Shaded areas below apply only to TH6320U/TH6220U or as otherwise noted. 1H/1C System (1 transformer) 1H/1C System (2 transformers) Power [1] Power (heating transformer) [1] [R+Rc joined by Slider Tab] [2] Power (cooling transformer) [1] Compressor contactor Compressor contactor 24VAC common [3]...
  • Page 5 Wiring heat pump systems Shaded areas below apply only to TH6320U/TH6220U or as otherwise noted. 1H/1C Heat Pump System 3H/2C Heat Pump System (TH6320U only) [10] Power [1] Power [1] [R+Rc joined by Slider Tab] [2] [R+Rc joined by Slider Tab] [2] Compressor contactor Compressor contactor (stage 1) 24VAC common [3]...
  • Page 6: Thermostat Mounting

    Thermostat mounting 1. Push excess wire back into the wall opening. 2. Close the UWP door. It should remain closed without bulging. 3. Align the UWP with the thermostat, and push gently until the thermostat snaps in place. 4. Turn the power on at the breaker box or switch.
  • Page 7: Fan Operation Settings

    System operation settings 1 Press the Mode button to cycle to the next available System mode. 2 Cycle through the modes until the required System mode is displayed and leave it to activate. NOTE: Available System modes vary by model and system settings.
  • Page 8 Installer setup (ISU) 1 Press and hold CENTER and buttons for approximately 3 seconds to enter advanced menu. 2 Press Select to enter ISU. 3 Press Select to cycle through menu setup options. 4 Press to change values or select from available options.
  • Page 9 Advanced setup options (ISU) # ISU ISU Name ISU Options (factory default in bold) Heat Stages / Backup Heat Stages Heat Stages: 1, 2 Backup Heat Stages: 0, 1 Fan Control in Heat 1 = Equipment Controls Fan 2 = Thermostat Controls Fan Aux/E terminal control (Fixed to 0 = Drive both Aux &...
  • Page 10 Advanced setup options (ISU) # ISU ISU Name ISU Options (factory default in bold) Adaptive Intelligent Recovery 0 = No 1 = Yes Note: Adaptive Intelligent Recovery (AIR) is a comfort setting. Heating or cooling equipment will turn on earlier, ensuring the indoor temperature will match the setpoint at the scheduled time.
  • Page 11: Installer System Test

    Installer system test To perform a System Test: 1 Press and hold CENTER and buttons for approximately 3 seconds to enter advanced menu. 2 Use to go to TEST. Press Select to enter System Test. 3 Use to change between Heat, Cool, Fan, Em Heat, or Ver (thermostat version information).
  • Page 12: Specifications

    Specifications Temperature Ranges Heat: 40 °F to 90 °F (4.5 °C to 32.0 °C) Cool: 50 °F to 99 °F (10.0 °C to 37.0 °C) Working Ambient Temperature 32 °F to 120 °F (0 C° to 48.9 °C) Operating Ambient Temperature 37 °F to 102 °F (2.8 °C to 38.9 °C) Shipping Temperature -20 °F to 120 °F (-28.9 °C to 48.9 °C)
  • Page 13: Troubleshooting

    Troubleshooting If you have difficulty with your thermostat, please try the following suggestions. Most problems can be corrected quickly and easily. Display is • Check circuit breaker and reset if necessary. blank • Make sure power switch for heating & cooling system is on. •...
  • Page 14: Customer Assistance

    33-00181EFS—19 M.S. Rev. 05-22 | Printed in United States © 2022 Resideo Technologies, Inc. All rights reserved. The Honeywell Home trademark is used under license from Honeywell International, Inc. This product is manu- factured by Resideo Technologies, Inc. and its affiliates.

This manual is also suitable for:

T6 proTh6220u2000Th6210u2001

Table of Contents

Save PDF