Download Print this page
S+S Regeltechnik THERMASGARD TM54 Series Operating Instructions, Mounting & Installation

S+S Regeltechnik THERMASGARD TM54 Series Operating Instructions, Mounting & Installation

Immersion ⁄ screw-in ⁄ duct temperature measuring transducer, calibratable, with multi-range switching and active output

Advertisement

Available languages

Available languages

  • ENGLISH, page 6

Quick Links

D G F r
6000-3060-0000-2XX 30600-2022 V212 03 ⁄ 2022
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Tauch- ⁄ Einschraub- ⁄ Kanal-Temperaturmessumformer,
kalibrierfähig, mit Mehrbereichsumschaltung
und aktivem Ausgang
G
Operating Instructions, Mounting & Installation
Immersion ⁄ screw-in ⁄ duct temperature measuring transducer,
calibratable, with multi-range switching
and active output
F
Notice d'instruction
Convertisseur de température à immerger ⁄ à visser ⁄ en gaine,
étalonnable, avec commutation multi-gamme
et sortie active
r
Руководство по монтажу и обслуживанию
Погружной ⁄ ввинчиваемый ⁄ канальный преобразователь температуры,
калибруемый, с переключением между несколькими диапазонами
и активным выходом
High-Performance-Verguss gegen Vibration,
mechanischer Belastung und Feuchtigkeit
High-performance encapsulation against
vibration, mechanical stress and humidity
P S - P R O T E C T I O N
P ERF EC T S E N S O R P R O T EC T I O N
TM 54 xx
S+S REGELTECHNIK GMBH
THURN-UND-TAXIS - STR. 22
90411 NÜRNBERG ⁄ GERMANY
FON +49 ( 0 ) 911 ⁄ 5 19 47- 0
mail@SplusS.de
www.SplusS.de
TM 54
(IP 54)
TM 54 - KV
(IP 65)
TM 54 - Q
(IP 65)
CARTONS
ET EMBALLAGE
PAPIER À TRIER

Advertisement

loading
Need help?

Need help?

Do you have a question about the THERMASGARD TM54 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for S+S Regeltechnik THERMASGARD TM54 Series

  • Page 1 P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N S+S REGELTECHNIK GMBH THURN-UND-TAXIS - STR. 22 90411 NÜRNBERG ⁄ GERMANY CARTONS FON +49 ( 0 ) 911 ⁄...
  • Page 2 D G F r TM 54 xx THERMASGARD ®  ø70 ~ 80 M20 x1.5 TM 54 - I TM 54 xx Maßzeichnung Anschlusskopf Dimensional drawing ø70 ~ 80 Connecting head Plan coté Tête de raccordement M20 x1.5 Габаритный чертеж Соединительная головка ø70 ø70 ~ 80...
  • Page 3: Technische Daten

    THERMASGARD ® TM 54 Rev. 2022 - V23 Kalibrierfähiger Temperaturmessumformer THERMASGARD ® TM 54 mit acht umschaltbaren Anschlussbild TM 54 - I Mess bereichen und stetigem Ausgang, mit Anschlusskopf aus Aluminium (optional mit Kabelver- schraubung oder M12-Steckverbinder nach DIN EN 61076-2-101) und geradem Schutzrohr. Ein 230V AC Grundgerät in vier Varianten durch Kombination mit Zubehör, z.B.
  • Page 4 Messumformer, kalibrierfähig, mit aktivem Ausgang Bürdendiagramm TEMPERATURBEREICHE: Bürdendiagramm Bei der Auswahl der Messumformerbereiche ist 4...20 mA darauf zu achten, dass die höchstzulässige Temperatur des Fühlers ⁄ Gehäuses nicht über schritten wird ! Umgebungstemperatur für den Messumformer: – 30 ...+ 70 °C zulässiger Bürdenwiderstand = siehe Bürdendiagramm Bereich...
  • Page 5 Montage und Inbetriebnahme Die Geräte sind im spannungslosen Zustand anzuschließen. Der Der Einbau hat unter Beachtung der Übereinstimmung der vorliegenden technischen Parameter der Thermometer mit den realen Einsatzbedin- Anschluss der Geräte darf nur an Sicherheitskleinspannung er folgen. gungen zu erfolgen, insbesondere: Folgeschäden, welche durch Fehler an diesem Gerät entstehen, sind von der Gewährleistung und Haftung ausgeschlossen.
  • Page 6: Technical Data

    THERMASGARD ® TM 54 Rev. 2022 - V23 Calibratable temperature measuring transducer THERMASGARD ® TM 54 with eight switchable Connectinga diagram TM 54 - I measuring ranges and continuous output, with connecting head made from aluminium (optionally with cable gland or M12 connector according to DIN EN 61076-2-101) and straight protective tube. 230V AC A basic unit in four variants through combination with accessories, eg, for robust applications with a separate immersion sleeve made from stainless steel.
  • Page 7 Measuring transducers, calibrateable, with active output Load resistance diagram TEMPERATURE RANGES: Load resistance diagram When selecting measuring transducer ranges, 4...20 mA it is necessary to ensure that the maximum temperatures permissible for sensor ⁄ enclosure are not exceeded ! Ambient temperature for measuring transducers: –...
  • Page 8 Installation and Commissioning Devices are to be connected under dead-voltage condition. Devices must Before mounting, make sure that the existing thermometer‘s technical parameters comply with the actual conditions at the place of utilization, only be connected to safety extra-low voltage. Consequential damages in particular in respect of: caused by a fault in this device are excluded from warranty or liability.
  • Page 9: Caractéristiques Techniques

    THERMASGARD ® TM 54 Rev. 2022 - V23 Convertisseur de température étalonnable THERMASGARD ® TM 54 avec huit plages de mesure Schéma de raccordement TM 54 - I commutables et sortie continue, tête de raccordement en aluminium (en option presse-étoupe ou connecteur M12 selon DIN EN 61076-2-101) et tube de protection droite.
  • Page 10 Convertisseur de mesure étalonnable avec sortie active Load resistance diagram PLAGES DE TEMPÉRATURE (TB): Diagramme de charge Lors de la sélection des plages de convertisseur, 4...20 mA il faut veiller à ce que la température maximale admissible de la sonde ⁄ du boîtier ne soit pas dépassée ! Température ambiante du convertisseur: –...
  • Page 11 Montage et mise en service Les raccordements électriques doivent être exécutés HORS TENSION. Effectuer l’installation en respectant la conformité des paramètres Veillez à ne brancher l’appareil que sur un réseau de très basse tension techniques correspondants des thermomètres aux conditions d’utilisa- de sécurité.
  • Page 12: Технические Данные

    THERMASGARD ® TM 54 Rev. 2022 - V23 Преобразователь температуры измерительный THERMASGARD ® TM 54 с восемью переключаемыми Схема соединения TM 54 - I диапазонами измерения и аналоговым выходом, с присоединительной головкой из алюминия (опцио- нально с резьбовым кабельным вводом или разъемом M12 согласно DIN  EN 61076-2-101) и прямой защитной...
  • Page 13 Преобразователи измерительные, калибруемые, с активным выходом Load resistance diagram ТЕМПЕРАТУРНЫЕ ДИАПАЗОНЫ: Нагрузочная диаграмма При выборе диапазона для измерительного преобразователя 4...20 мA следует учитывать, что не разрешается превышение максимальной допустимой температуры датчика  ⁄ корпуса ! Температура окружающей среды для измерительного преобразователя: –...
  • Page 14 Монтаж и ввод в эксплуатацию Приборы следует устанавливать в обесточенном состоянии. Подключение Монтаж следует осуществлять с учетом соответствия прилагаемых должно осуществляться исключительно к безопасно малому напряжению. технических параметров термометра реальным условиям эксплуатации, Повреждения приборов вследствие несоблюдения упомянутых требований в особенности: –...
  • Page 15 D G F r THERMASGARD ®  TM 54 + MF - 06 - M Kanaltemperatur - TM 54 + fühler mit Montage- TH ⁄ xx ⁄ 90 flansch aus Metall TM 54 + Edelstahltauchhülse Duct temperature TM 54 + mit Halsrohr TH - VA ⁄...
  • Page 16 Reprint in full or in parts requires permission from S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.

This manual is also suitable for:

Tm54 seriesTm 54-kvTm 54-q