Contactor Specifications; Dynamic Braking Resistors - PowerTec Regenerative Brushless DC Motor Control 1000AR Installation And Operation Instruction Manual

Regenerative brushless dc motor control
Table of Contents

Advertisement

18
Page
C O N TAC TO R S P E C I F I C ATI O N S
1.77"
13
21
31
1.66"
14
22
32
TOP VIEW
1.54"
BOTTOM VIEW
We choose DB resistors for their ability to absorb high inrush currents and to accept large amounts of
power for short periods of time. Typical DB resistors can absorb ten times their power rating for up to five
seconds. The resistors must then cool down to ambient temperature before they can dissipate their full
rating again (usually a few minutes). It is possible to extend the ratings by about three times with power
resistors by forced-air cooling.
You can derive an approximate value of dynamic braking resistor from the bus voltage and the full
load current on the nameplate of the motor:
Three resistors (or groups of resistors) are necessary. The power rating of each should be:
These formulas are very general, and results will vary from motor to motor. For dynamic braking
tailored to your application, consult POWERTEC Engineering.
1000AR
Model
Installation and Operation Manual
If you want to operate an Output or DB Contactor directly
from the Model 1000AR, you must choose a coil that draws
less than 50 milliamps DC.
A1
41
connections for direct operation of the contactor (use the
same connections for Dynamic Braking). The coil must be
48VDC and draw less than 50 ma DC (2.4 Watts). This is the
most power available from the Model 1000AR drive's supplies.
Contactor Control board, as shown in the drawing on page 11.
Use the same drawing for the Output Contactor. Maximum
current for the Contactor Control board is 1 Amp at 230 VAC.
42
A2
open auxiliary for an Output Contactor. The contactor does
not make or break with current in the power contacts. Choose
0.19"
the contact ratings only on the basis of carrying the current.
power poles and a normally open auxiliary. The contacts make
with current present, but they do not break current in the
dynamic braking operation. Choose contacts accordingly.
1.25"
series by AEG Industries. The model used for the Output
Contactor is part number SH-04.40 and the Dynamic Braking
is SH-04.13. Contact ratings are 16 Amps.
D Y N AM I C B R AK I N G R E S I S TO R S
Each Resistor Value ~ -----------------------------------
Power > 0.02 X (Buss Voltage)
6/4/2001
The Output Contactor drawing on page 11 shows the
To use a 115VAC or 230 VAC coil, you need a 156-012
You need three normally open power poles and a normally
For Dynamic Braking, you need three normally closed
The contactor outline sketched at left is from the SH-04
Bus Voltage X 0.47
Motor FLA
2
/ (Resistor Value)
© copyright 1997 by Powertec