Page
NOMINAL
AC LINE
VOLTAGE
230
230
230
230
230
230
230
230
230
380
380
380
380
380
380
380
460
460
460
460
460
460
Indicates drives supplied with separate bus loader.
The Model 1000AR drives will operate on power line frequencies from 48 to 62 hertz.
The tolerance of the input voltage is +10% to -10% of the voltage listed on the nameplate. A service must be
capable of supporting the starting current of AC motors without dropping more than 10%. Brief power line disturbances
may trip a drive supplied with less than 95% of the nominal line voltage.
Do not measure the input voltage while the drive is not running. This neglects the effects of load on the power
source. Measure the actual input line voltage while the control is operating the motor in a loaded condition.
Brief power line disturbances will not normally disturb the Model 1000AR drives. The Model 1000AR drives do not
generate significant noise back onto the power service. Events that distort the AC waveform may lower the bus voltage.
These may trigger an under-voltage or power loss condition.
One of the most frequent problems encountered with digital type equipment is electrical noise. Noise is a
treacherous problem that is capable of causing destructive results. It can also cause intermittent and annoying problems.
The methods used in the installation of the equipment plays a large part in prevention of electrical noise problems in
operation. Any digital type control requires that extra care be taken in installation. Pay attention to the grounding of the
equipment, the shielding of wires and cables, and the placement of wires in the conduit runs. Pay attention to the
sections of this manual that address the precautions against noise. This also applies to peripheral equipment.
When you use other manufacturer's equipment in a system, follow their directions regarding noise suppression and
protection. Pay particular attention to power and grounding requirements.
1000AR
Model
Installation and Operation Manual
HORSE-
KILO-
POWER
WATTS
½
0.37
¾
0.56
1
0.75
1.5
1.1
2
1.5
3
2.2
5
3.7
7.5
5.6
10
7.5
1
0.75
1.5
1.1
2
1.5
3
2.2
5
3.7
7.5
5.6
10
7.5
2
1.5
3
2.2
5
3.7
7.5
5.6
10
7.5
15
11
Notes
6/4/2001
MAXIMUM
CONTINUOUS
INPUT
AC LINE
KVA
CURRENT
1.4
0.550
1.8
0.725
2.4
0.950
3.6
1.450
4.9
1.950
7.3
2.900
12.1
4.825
18.1
7.200
23.9
9.525
1.5
0.975
2.2
1.450
2.9
1.925
4.4
2.875
7.3
4.810
10.9
7.150
14.1
9.250
2.4
1.910
3.5
2.800
5.9
4.750
8.9
7.100
11.4
9.050
17.8
14.150
MAXIMUM
HEAT
OUTPUT IN
WATTS
35
42
60
85
122
165
232
281
385
36
55
70
105
142
178
222
113
144
200
258
355
475
© copyright 1997 by Powertec