Specifications

Specification
Storage capacity
Temperature setting
TPR valve setting
Solar circuit relief valve
Max supply pressure
Min supply pressure
Water connections- tank
Water connections- collector
Collector(s) type
Supply voltage
Solar circuit fluid
Anodes
Solar circuit pump
Solar circuit aux pump (optional)
* Approximate propylene glycol / water ratio. Refer to 'Commissioning Procedure' on page
57 for more information.
Solar controller
Solar pump
Heating unit
(591 models only)
Gas Booster
(596 models only)
Heating unit rating depending upon model
Amps
Element circuit resistance (ohms)
Booster capacity
Booster temperature setting
Input
Booster capacity
Booster temperature setting
For complete gas booster specifications refer to Integrity 26 Service Manual TM023.
TM024 Premier Loline Solar Drain back Service Instructions REV: A
D.O.I: 12/12/2007
This document is stored and maintained electronically by
Power Consumption
3 Watts
Constant load
Maximum load at solar heating cycle start up
165 Watts
(for approximately two (2) minutes)
50 Watts
Average load during the solar heating cycle
2.4kW, 3.6kW
Consumption when booster heating unit is operating
or 4.8kW
depending upon model
146W
When anti frost device is activated
Electric Booster Specifications (591 models only)
Gas Booster Specifications (596 models only)
590, 591 & 596 Models
800kPa (680kPa with ECV)
Inlet RP¾/20, Outlet RP¾ /20
Hot pipe ½" BSP, Cold pipe ½" BSP
S200 or T200
220 – 250 Volts AC 50Hz
*4.5 Litres propylene glycol / 11.5 Litres water
2.4kW
10
22 – 26
4
Service. All printed copies not bearing this statement in RED are deemed "uncontrolled"
270 Litres
60ºC
1000kPa
200kPa
200kPa
2 X 1153mm
127.8 ohms
127.8 ohms
3.6kW
15
15 – 17
125 litres
60ºC
199mJ
26L/min
60ºC
4.8kW
20
11 - 13