Page 1
Lely Grazeway R Return Box Operator Manual EN - English Original 5.1531.8501.0 A Lely Industries N.V. www.lely.com...
Page 2
in n o vato rs in ag ric u ltu re INTENTIONALLY BLANK...
Page 3
Lely reserves all rights with respect to its trademarks. Any unauthorized use of any Lely-owned trademark or any use of a trademark that is confusingly similar to, or likely to cause confusion with a Lely-owned trademark, would constitute infringement of Lely’s exclusive rights. All rights reserved.
Page 4
in n o vato rs in ag ric u ltu re INTENTIONALLY BLANK Trademarks, Copyright and Disclaimer...
Page 5
in n o vato rs in ag ric u ltu re List of included Amendments Issue Date Chapter(s) Remarks (yyyy/mm) 2018/02 Initial issue 2019/02 Removed: Installation Added: EC declaration and WEE Changed: Structure and layout List of included Amendments...
Page 6
in n o vato rs in ag ric u ltu re INTENTIONALLY BLANK List of included Amendments...
Page 7
All information in this manual has been compiled with care. Lely shall not be liable for errors or faults in this manual. The recommendations are meant to serve as guidelines. All instructions, pictures and specifications in this manual are based on the latest information that was available at the time of publication.
Page 8
in n o vato rs in ag ric u ltu re Figure 1. Type and serial number plate We suggest that you complete the table below with the type and serial numbers of your machine. This makes sure that you can easily find the information. Type number Serial number Preface...
Cows can only open the gates of the Grazeway R in one direction. Each cow has an identification tag. The Grazeway R has a cow identification system and detects the ID of each cow returning into the barn (or going to the pasture). This ID is sent to T4C, the Lely farm management software.
Page 12
INTENTIONALLY BLANK The Lely Grazeway Return Box...
in n o vato rs in ag ric u ltu re Safety Signal Icons Note the use of the signal words DANGER, WARNING and CAUTION with the safety messages. The signal word for each message uses the following guidelines: Danger Indicates a hazardous situation which, if not avoided, will result in death or serious injury.
• box. • Know the emergency medical center number for your area. Contact your local Lely service provider if you have any questions. • 2.2.2 Electrical Safety Only an authorized electrician must install the electrical power supply for the return box.
in n o vato rs in ag ric u ltu re Specifications Specifications and Requirements General Operational Conditions Ambient temperature -15 to +40 °C (5 to 104 °F) Humidity 5 - 99% non condensing Power Supply 24 VDC Power supply Current Connected to Power box 24 VDC power supply...
ISO identification reader • Portal, Frames and Gates The Grazeway R has a portal and an entrance made of several frames and plates and two sets of Texas gates. All frames and gates are galvanised. Control Box The control box is installed on top of the portal under a cover. Inside the control box the PCB on which the Lely software runs is installed.
in n o vato rs in ag ric u ltu re ISO Identification Reader The ISO identification reader has a Velos control box and an antenna PCB, which both are installed inside the control box. The antenna is a ring through which the cow steps before she goes through the second Texas gate. Description...
Operating Instructions General Instruction There are no operating instructions for the Grazeway R other than adjustments in T4C. For more information see the online instruction guide “Your guide”. Operating Instructions...
Page 20
in n o vato rs in ag ric u ltu re INTENTIONALLY BLANK Operating Instructions...
in n o vato rs in ag ric u ltu re Preventive Maintenance Clean the Return Box Unexpected cow movement. Risk of being crushed or trampled. Block the cow traffic. Do not spout water on the control box this can cause damage to the electronics. Preventive Maintenance...
Page 22
Figure 4. How to clean the parts of the Grazeway R KEY: 1. Do not spout water on the control unit with the control box - 2. Frames, plates and gates, cleaning with a high pressure cleaner is allowed Use a high pressure cleaner to clean the portal and gates (2).
A Texas gate does not move The gate is tied. Untie the gate. (easily). If the problem persists. Call your local Lely service provider. Cow ISO tags are not identified The ring antenna is not Tighten the bolts of the ring connected correctly.
Page 24
in n o vato rs in ag ric u ltu re INTENTIONALLY BLANK Troubleshooting...
Lubricants and fluids must be disposed correctly to prevent pollution of the environment. Read the safety data sheets of the used lubricants and fluids for correct disposal. All lubricants and fluids must be disposed in compliance with the local rules and regulations. Contact your local authority or local Lely service provider for further details. Disposal...
Page 26
in n o vato rs in ag ric u ltu re INTENTIONALLY BLANK Disposal...
WEEE directive, require special reuse and recycling processing. For this reason, Lely Industries N.V. has arranged that this product can be recycled at the local recycling/ disposal companies to collect and recycle this product at no cost to you.
Page 28
in n o vato rs in ag ric u ltu re INTENTIONALLY BLANK WEEE...
Need help?
Do you have a question about the Grazeway R and is the answer not in the manual?
Questions and answers