FLUE SYSTEM
(Fumes duct, flue and chimney pot)
This chapter has been drawn up pursuant to European
regulations EN 13384, EN 1443, EN 1856 and EN
1457.
The installer must observe both these and any
other local regulations.
This manual does not in any way substitute such
regulations.The product must be connected to a flue
system which ensures that the fumes produced by
combustion are exhausted in complete safety.
Before positioning the product, the installer must
check that the flue pipe is properly rated.
SMOKE CHANNEL, CHIMNEY FLUE
The smoke channel (pipe that connects the smoke
outlet of the fi replace with the chimney flue inlet)
and the chimney flue must, along with other legal
provisions:
• receive the discharge for a single product (multiple
product discharges are not permitted together)
• have a mainly vertical development
• no section should have a reserve slope
• have an inner section preferably circular and
however with a ratio between sides lower than 1,5
• complete the roof with the appropriate chimney
stack: direct discharge is forbidden on walls or
towards closed spaces, even if outdoors
• be created with materials with a fi re reaction class
A1 pursuant to UNI EN 13501 or similar national
standard
• be appropriately certifi ed, with an appropriate
fi replace plate, if metal
• keep the initial section
INSTALLATION
Electricity lines
There must be no electricity lines in the
walls or ceiling of the fi replace installation
area.