Boiler Fixing; Probe-Electrode Positioning - Riello Gulliver BS3/M TXL Installation, Use And Maintenance Instructions

Forced draught gas burner
Table of Contents

Advertisement

3.2 BOILER FIXING

To fit the burner to the boiler it is necessary to carry out the following:
Widen, if necessary, the insulating gasket holes (3, fig. 3).
Fix the flange (5) to the boiler door (1) using four screws (4) and (if necessary) the nuts (2) interposing
the insulating gasket (3) but keep unloosing one of the two upper screws (4) (see fig. 2).
Put on the flange (5) the burner combustion head, tighten the flange with the screws (6) and lock the
loose screw (4).
N.B.: The burner can be fixed with the variable dimension (A) (see fig. 4). Anyway, make sure that the
combustion head crosses completely the boiler door thickness.
Fig. 2
3.3

PROBE-ELECTRODE POSITIONING

ATTENTION
Ensure that the plate (3, fig. 5) is always
inserted in the flattening of the electrode.
Lean the probe insulator (4) against the cup (2).
20050873
S7002
TYPE
A
917T2
267 - 282
3.5
±
0.3
3
6
GB
Fig. 3
D5012
A
Fig. 4
D5011
Fig. 5
2
31
±
0.3
1
D6088
4

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

20050820

Table of Contents