EAN-FLIR Cameras
8 RHP-BOSON Interface Module - FLIR Boson Camera
This section discusses the FLIR Boson camera and the
International (PN: RHP-BOS-VPC-TTL-IF).
8.1
Configuration Example - 1500-OEM
Power is supplied externally on the RHP interface module. The analog video is processed through the
1500-OEM. Command and control are established through the following methods:
Serial-to-serial or Ethernet-to-serial passthrough
•
Camera configuration - FLIR GUI
•
User implementation of the FLIR Boson command packet (FLIR Serial Line Packet FSLP)
•
Raw bytes (in hex) sent to the camera - Panel Plus main menu File » Send Command
•
Commands Can be combined into a MACRO for easy reuse during bench setup. They can also be
combined in a LUA script and sent.
Additional technical documentation can be found the
8.1.1 Hardware Connection
Table 2
and
Figure 19
connected to the 1500-OEM. Serial connections are 3.3V TTL on both the 1500-OEM and interface
module. Analog video is NTSC. Power to the interface module can be supplied externally.
RHP-BOSON VPC TTL Interface Module
P3 (Pins)
1
2
3
4
5
6
7
FLIR Boson
Figure 19: RHP-BOSON VPC TTL Interface Module - 1500-OEM Example
© SightLine Applications, Inc.
below show an example of how the RHP-BOSON interface module can be
Table 2: Connection Example RHP-BOS to 1500-OEM (J3)
Description
Vin (+5V DC)
Ground
Analog Video Out
Ground
RX »
TX «
Ground
RHP-BOSON VPC TTL
Interface Module
P3
PWR
RHP-BOON VPC TTL Interface Module
OEM-Cameras
1500-OEM
J3 (Pins)
Description
1
Analog Video In (Cam0)
2
Ground
6
5
7
Ground
Analog Video
TTL Serial
Ethernet / PWR
from RHP
webpage.
Serial Port 0
1500-OEM
J3
19