SightLine SLA-3000-mIO Manual

Icd-adapter boards
Hide thumbs Also See for SLA-3000-mIO:

Advertisement

ICD-Adapter Boards
2024-08-15
Exports:
Export Summary Sheet
EULA:
End User License Agreement
Web:
sightlineapplications.com
1
Overview ................................................................ 1
1.1
1.2
Sightline Software Requirements .......................... 1
2
Safe Device Handling .............................................. 1
3
Operating Temperature ......................................... 2
4
FFC-FPC Adapter Board Connections ..................... 2
5
Serial Ports - GPIO - I2C .......................................... 3
5.1
Serial Ports ............................................................. 3
5.2
GPIO ....................................................................... 4
5.3
I2C .......................................................................... 5
6
System Interface Adapter Boards .......................... 7
6.1
SLA-3000-mIO (3000-OEM only) ............................ 7
6.1.2 SLA-3000-mIO Board Tab Removal ........................ 9
6.2
SLA-3000-IO (3000-OEM only) ............................... 9
6.2.2 Rev D - J5 Access to Serial 0 or 1 .......................... 12
6.2.3 Rev C - J5 Access to Serial 0 or 1 .......................... 12
6.3
SLA-DIST ............................................................... 13
7
Camera Interface Adapter Boards ....................... 14
7.1
Camera Input Adapter Board IDs ......................... 14
7.2
I2C Clock Rate Compatibility ................................ 14
7.3
SLA-4000-MIPI-IN ................................................. 14
7.4
SLA-4000-STM ...................................................... 17
CAUTION: Alerts to a potential hazard that may result in personal injury, or an unsafe practice that causes damage to the equipment
if not avoided.
IMPORTANT: Identifies crucial information that is important to setup and configuration procedures.
Used to emphasize points or remind the user of something. Supplementary information aids in the use or understanding of the
equipment or subject, which is not critical to system use.
© SightLine Applications, LLC
Sales:
sales@sightlineapplications.com
Support:
support@sightlineapplications.com
7.5
SLA-4000-HDMI .................................................... 18
7.6
SLA-4000-PI22 ...................................................... 21
7.7
SLA-4000-PI15 ...................................................... 22
7.8
SLA-USB-FPC-C ..................................................... 24
7.9
SLA-3000-Sony / Tamron ..................................... 25
7.10 SLA-3000-CL ......................................................... 26
7.11 SLA-3000-CLK ....................................................... 28
7.12 SLA-MIPI-AB (Dual Analog) .................................. 29
7.13 SLA-3000-AB (Dual Analog) .................................. 30
7.14 SLA-3000-HDSDI-IN .............................................. 32
7.15 SLA-3000-FPC ....................................................... 33
7.16 SLA-3000-FFC (Legacy) ......................................... 34
7.17 SLA-3000-HDMI .................................................... 35
7.18 SLA-3000-HIT (Legacy) ......................................... 36
8
Video Output Accessory Boards........................... 38
8.1
SLA-KEL-CL-OUT ................................................... 38
8.2
8.3
FFC HDMI Output Interface ................................. 42
8.3.2 SLA-FFC-HDMI ...................................................... 43
8.3.3 SLA-HDMI-SDI ...................................................... 44
9
Questions and Additional Support ....................... 46
Appendix - Standard Connector Pinouts ........................ 47
Phone: +1 (541) 716-5137

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SLA-3000-mIO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SightLine SLA-3000-mIO

  • Page 1: Table Of Contents

    SLA-3000-mIO (3000-OEM only) ......7 7.15 SLA-3000-FPC ............33 6.1.1 mIO Serial Port Signal Level Configurations ... 8 7.16 SLA-3000-FFC (Legacy) ......... 34 6.1.2 SLA-3000-mIO Board Tab Removal ......9 7.17 SLA-3000-HDMI ............ 35 SLA-3000-IO (3000-OEM only) ....... 9 7.18 SLA-3000-HIT (Legacy) ......... 36 6.2.1 IO Serial Port Signal Level Configurations ....
  • Page 2 Updated Serial Port and GPIO tables. 2022-08-25 Added SLA-4000-HDMI adapter board section. Designated serial port in the SLA-HDMI-SDI hardware block diagram for SightLine internal. Added HDMI compliance and 2022-08-22 specification notes. Added 1080p30 and 180P60 (3G) SMPTE compliance notes to SLA-3000-HDSDI-IN.
  • Page 3 Added RS-232 note for default serial port configuration in the 3000-mIO board section. 2018-10-31 Added 3.3V and 5.0V test points note to the SLA-3000-IO Connector Descriptions table. 2018-10-25 Add resistor configuration for SLA-3000-mIO board serial out (RS-232/TTL). 2018-09-10 Added supply voltage level compatibility statement to mIO and IO board sections. 2018-08-09 Added Operating Temperature, mIO adapter board, and tab breaking sections.
  • Page 4: Overview

    For supported camera-side adapter boards see the ICD-OEM-Camera-Side-Interfaces.  CAUTION: Any customer modifications to SightLine OEM and adapter boards will void the warranty and can potentially damage the board. Before attempting any modifications, please contact Support.  Additional product support documentation is available on the Product Documentation page.
  • Page 5: Operating Temperature

    Close the flip-lock connector.  Contact Surface If the ribbon cable is moved at any Facing Down when time before the flip-lock is closed Inserting repeat the process starting at step 1. Figure 1: FPC / FFC Connections © SightLine Applications, LLC...
  • Page 6: Serial Ports - Gpio - I2C

    J4, 5 3.3V  All serial ports are 3.3V TTL. When using a SightLine adapter board with a 3-pin connector, use the CAB-03xx for a breakout to either a pigtail, Molex-to-Molex, or DB-9 connector.  Serial Port 5 is internal use only.
  • Page 7: Gpio

    Out of the six GPIOs, four are utilized to determine the address of the camera input adapter board. This allows the SightLine software to identify the connected adapter board accurately. To achieve this, the four GPIOs are equipped with 10K resistors that pull them either up or down, depending on the address of the adapter board.
  • Page 8 Available on Rev C for general I/O. SLA-3000-HDSDI-OUT VOUT J4,3 gpio22 Not available on Rev A or B 5.3 I2C Table 10: 3000-OEM I2C Addresses on SightLine Hardware 3000-OEM Vin0 (Cam0) Vin1 (Cam 2) I2C0 (/dev/i2c-1) I2C3 (/dev/i2c-4) Other Addresses...
  • Page 9 ICD-Adapter-Boards Table 11: I2C 4000-OEM and 4100-OEM Addresses on SightLine Hardware 4000-OEM and 4100-OEM Description of Bus I2C0 (/dev/i2c-1) This bus connects to local resources as well as adapter boards on J6. Addresses Used for: 0x1C UART3 Write (U10) 0x2C...
  • Page 10: System Interface Adapter Boards

    The minimum accessory board revision level that is mechanically compatible with the mIO board is shown in Table 14. All adapter boards that are mechanically compatible with the 3000-mIO are marked with a mIO label. Table 14: Minimum Revisions SLA-3000-mIO Board Compatibility Adapter Board Min Rev 3000-mIO Adapter Board Min Rev 3000-mIO...
  • Page 11: Mio Serial Port Signal Level Configurations

     Changing the serial port signals is a low-risk modification, however any customer alterations to the board will void the warranty. SightLine can provide custom boards that can meet specific configuration needs while maintaining board warranty. Please contact Support for more information.
  • Page 12: Sla-3000-Mio Board Tab Removal

    2. Grip the board tab with a pair of flat nose pliers. 3. Use a back-and-forth motion until the tab breaks free. Figure 4: SLA-3000-mIO Board Tab Removal 6.2 SLA-3000-IO (3000-OEM only) The 3000-IO board is a system interfaces adapter board which is optimized for connections in a bench test environment.
  • Page 13 53047-0310 / Molex Port Voltage Levels for configuration options. and 50058-8000 (terminals) ST10S008V4BR1800 / JAE MicroSD card slot 47659-1000 / Molex HDMI video output DF12NB(3.0)-60DP-0.5V(51) / Digital video output - same pinout as 3000-OEM (J2) DF12NB(3.0)-60DS-0.5V(51) Hirose © SightLine Applications, LLC...
  • Page 14: Io Serial Port Signal Level Configurations

     Changing the serial port signals is a low-risk modification, however, any customer alterations to the board will void the warranty. SightLine can provide custom boards that can meet your specific configuration needs while maintaining board warranty. Please contact Support for more information.
  • Page 15: Rev D - J5 Access To Serial 0 Or 1

    J10 - Serial 1 Levels Zero Ohm Resistor Do Not Install RS-232 (default) R16 and R18 R17 and R19 3.3V TTL R17 and R19 R16 and R18 Figure 7: Rev D board Port Configuration Resistor Locations © SightLine Applications, LLC...
  • Page 16: Sla-Dist

    Connector J2: Power to OEM Signal Signal Ground Ground Connector J3: Ethernet to OEM Port uses the standard pinout defined in Appendix - Standard Connector #5 Connector J4: Power Connector Signal Signal PWR_IN - 12V Nominal Ground © SightLine Applications, LLC...
  • Page 17: Camera Interface Adapter Boards

    SightLine adapter board schematics, make sure any decoder or other adapter hardware is enabled with the GPIO pins at 0xD. It is common for SightLine designed adapter boards to repurpose these GPIO pins once the board ID is read. The same cannot be assumed for generic adapter boards.
  • Page 18 Molex 051021-0800 Molex 53398-0471 Power Connector Molex 051021-0400 Hirose PN: DF12NB(3.0)-80DS-0.5V(51) on 3000- DF12(3.0)-80DP-0.5V Digital Video Connector OEM/1750-OEM/4000-OEM/4100-OEM adapter boards.* See the connector summary for the individual adapter boards for more information about this mating connector. © SightLine Applications, LLC...
  • Page 19 3.3V TTL level. Any conversion from a Connector #8 Designation MIPI Board Specific Value VIOSEL voltage level will be done on GPIO0/ID0 GPIO_436 the external adapter boards, e.g., SLA- 3000-FPC. GPIO1/ID1 GPIO_437 GPIO2/ID2 GPIO_438 GPIO3/ID3 GPIO_439 GPIO4 GPIO_440 GPIO5 GPIO_441 © SightLine Applications, LLC...
  • Page 20: Sla-4000-Stm

    Molex 051021-0800 The KEL ribbon cable length should be as short as possible to ensure video quality and reduce EMI susceptibility. SightLine provides a 10cm cable within camera interface kits. A KEL cable length greater than 15cm is not recommended. There are COTS sources for alternate length KEL cables to help with custom integrations.
  • Page 21: Sla-4000-Hdmi

    Serial RX4 Ground Serial TX7 Serial RX7 GPIO6 GPIO13 (Open drain FET), 1A Max 7.5 SLA-4000-HDMI The SLA-4000-HDMI board allows HDMI video sources to be connected to the 1750-OEM, 4000-OEM, and 4100-OEM through the MIPI FFC port. © SightLine Applications, LLC...
  • Page 22 Molex 051021-0800 The HDMI ribbon cable length should be as short as possible to ensure video quality and reduce EMI susceptibility. SightLine provides a 10cm cable within camera interface kits. An HDMI cable length greater than 10cm is not recommended.
  • Page 23 TX0OUT _P TX1OUT _P TX1OUT _N TX2OUT _N TX2OUT _P Description Connector J4: IO Connector Ground (All signals at 3.3V levels) Serial TX4 Serial RX4 Ground Serial TX7 Serial RX7 GPIO6 GPIO13 (Open drain FET), 1A Max © SightLine Applications, LLC...
  • Page 24: Sla-4000-Pi22

    1, 7, 10, 13, 16, 19, 22, 25, 28 Ground  2, 3, 4 The mating cycle rating for this GPIO IN0 (1.8V) connector is 20 cycles. GPIO IN1 (1.8V) I2C SDA (1.8V) I2C SCL (1.8V) © SightLine Applications, LLC...
  • Page 25: Sla-4000-Pi15

    1.00 in x 1.00 in (25.4 mm x 25.4 mm) Weight: 3.14 grams Drawing: SLA-4000-PI15 STEP File: SLA-4000-PI15 STEP Rev History: B: Initial production release. C: DFM improvements. No form, fit or function change. Figure 18: SLA-4000-PI15 Board © SightLine Applications, LLC...
  • Page 26 MIPI CSI Lane 3 N MIPI CSI Lane 3 P Connector J1: PI Camera Connector Signal Signal P3P3V MIPI_CSIO_LANE1_P I2C_SDA_3V3 (3.3V) MIPI_CSIO_LANE1_N I2C_SCL_3V3 (3.3V) Ground CAM_IO1 (3.3V) MIPI_CSIO_LANE0_P CAM_IO0 (3.3V) MIPI_CSIO_LANE0_N Ground Ground MIPI_CSIO_CLK_P Shield/Ground MIPI_CSIO_CLK_N Shield/Ground Ground © SightLine Applications, LLC...
  • Page 27: Sla-Usb-Fpc-C

    Connector J1: USB 3 over FPC Signal Signal Signal VCC2 D2_P SSRX2_P VCC2 SSTX2_N D2_N SSRX2_N SSTX2_P Connector J2: USB C Receptacle Signal Signal SSTX2_P SSTX2_N VCC2 VCC2 D2_P D2_P D2_N D2_N VCC2 VCC2 SSRX2_N SSRX2_P © SightLine Applications, LLC...
  • Page 28: Usbc-Fpc Cable Connection Guidelines

    4100-OEM (J6) *The KEL ribbon cable length should be as short as possible to ensure video quality and reduce EMI susceptibility. SightLine provides a 10cm cable within camera interface kits. A KEL cable length greater than 15cm is not recommended. There are COTS sources for alternate length KEL cables to help with custom integrations.
  • Page 29: Sla-3000-Cl

    1.71 in x 0.96 in (43.4 mm x 24.4 mm) (not including SDR) Weight: 8.69 grams Drawing: SLA-3000-CL STEP File: SLA-3000-CL STEP Rev History: A: Initial production release. B: Add J4 to expose GPIO, and I2C. Figure 25: 3000-CL Figure 26: SLA-3000-CL Connector Callouts © SightLine Applications, LLC...
  • Page 30 I2C - SCL Specific serial, GPIO, and I2C designation depends on whether the adapter board is connected on 3000 VIN0, 3000 VIN1, 4000 J6, or SLA-4000-MIPI-IN. See the Serial Ports - GPIO - I2C section for more information. © SightLine Applications, LLC...
  • Page 31: Sla-3000-Clk

    Molex 51021-0500 (housing) and 0500588000 (terminals) The KEL ribbon cable length should be as short as possible to ensure video quality and reduce EMI susceptibility. SightLine provides a 10cm cable within camera interface kits. A KEL cable length greater than 15cm is not recommended. There are COTS sources for alternate length KEL cables to help with custom integrations.
  • Page 32: Sla-Mipi-Ab (Dual Analog)

    Revision: Dimensions: 1.08 in x 0.944 in (27.43 mm x 26.26 mm) Weight: 4.48 grams Drawing: SLA-MIPI-AB STEP File: SLA-MIPI-AB STEP Rev History: C: Initial production release. Figure 29: SLA-MIPI-AB Board Figure 30: SLA-MIPI-AB Connector Callouts © SightLine Applications, LLC...
  • Page 33: Sla-3000-Ab (Dual Analog)

    In software version 3.00.07 analog inputs are now supported on the SLA-4000-MIPI-IN board. Revision: Dimensions: 1.71 in x 0.96 in (43.4 mm x 24.4 mm) Weight: 7.59 grams Drawing: SLA-3000-AB STEP File: SLA-3000-AB STEP Rev History: A: Initial production release. Figure 31: SLA-3000-AB -Dual Analog Input © SightLine Applications, LLC...
  • Page 34 Ground Specific serial, GPIO, and I2C designation depends on whether the adapter board is connected on 3000 VIN0, 3000 VIN1, 4000 J6, or SLA-4000-MIPI-IN. See the Serial Ports - GPIO - I2C section for more information. © SightLine Applications, LLC...
  • Page 35: Sla-3000-Hdsdi-In

    A: Initial production release. Obsolete due to noise. detected in video image. Limited shipment. B: Updated PCB layout to correct noise artifacts in video image. C: Updated component placement for SLA-3000-mIO board Figure 33: SLA-3000-HDSDI IN compatibility. E: P1 component changed to 80POS Hirose, U3 moved to the top of the board.
  • Page 36: Sla-3000-Fpc

    VINA_VSYNCC VINC_D2 Ground VINA_HSYNCC Ground P5V*** FLASH_RX Ground P3P3V*** TRIG_TX VINC_D1 P3P3V*** VINC_D11 VINC_D0 VIOSEL_IN* VINC_D10 I2C0_SCL P5V*** VINC_D9 I2C0_SDA P5V*** VINC_D8 Ground VINC_D7 VINC_D15 MCLK VINC_D6 ID1_GP0_C VINC_D5 VINC_D14 PCLK_C VINC_D4 VINC_D13 AIRBORNE_DET VINC_D3 VINC_D12 © SightLine Applications, LLC...
  • Page 37: Sla-3000-Ffc (Legacy)

    Provides camera interface for FLIR Tau, FLIR Quark, and DRS Tamarisk cameras. Camera-side adapter boards are required for these interfaces. See the ICD-OEM-Camera-Side-Interfaces for supported camera-side adapter boards. SightLine is not actively stocking FFC camera interface boards. For new designs, SightLine recommends using FPC camera interface boards. Contact Sales for more information. Revision: Dimensions: 1.71 in x 0.96 in (43.4 mm x 24.4 mm)
  • Page 38: Sla-3000-Hdmi

    3000-HDMI board, which decodes the video and sends it to the OEM. If the camera is powered on after the OEM, the camera detects that it is connected and then reads the EDID data. © SightLine Applications, LLC...
  • Page 39: Sla-3000-Hit (Legacy)

    Serial Ports - GPIO - I2C section for more information. 7.18 SLA-3000-HIT (Legacy) Provides camera interface for Hitachi block cameras. These cameras are no longer available, and SightLine is not actively stocking SLA-3000-HIT boards. For new designs contact Sales for more information.
  • Page 40 RX - 3.3V TTL Specific serial designation depends on whether the adapter board is connected on 3000 VIN0, 3000 VIN1, 4000 J6, or SLA-4000-MIPI-IN. See the Serial Ports - GPIO - I2C section for more information. © SightLine Applications, LLC...
  • Page 41: Video Output Accessory Boards

    Camera Link Cable *The KEL ribbon cable length should be as short as possible to ensure video quality and reduce EMI susceptibility. SightLine provides a 10cm cable within camera interface kits. A KEL cable length greater than 15cm is not recommended. There are COTS sources for alternate length KEL cables to help with custom integrations.
  • Page 42: Sla-3000-Hdsdi-Out (3000-Oem Only)

    MFG Part Number For Panel Thickness 12226-8250-00FR No Panel 8.2 SLA-3000-HDSDI-OUT (3000-OEM only) Provides HDSDI output video. Connects to the digital video output connector (J2) on the 3000-OEM. See the SLA-3000-mIO board for tab removal instructions. © SightLine Applications, LLC...
  • Page 43 (terminals) Table 59: SLA-3000-HDSDI-OUT Connector Descriptions Connector Description Connector J1: HD-SDI MCX 75 Ohms, MCX vertical jack receptacle coax connector. Connector J2: Digital Video Output Connects to the digital video output connector (J2) on the 3000-OEM. © SightLine Applications, LLC...
  • Page 44 Ground GPIO22 3.3v TTL* I2C0 - SDA I2C0 - SCL GP0_22 and GPIO22 are the same and available on Rev C and above for general purpose use. No GPIOs are available on Rev A or B. © SightLine Applications, LLC...
  • Page 45: Ffc Hdmi Output Interface

     If the HDMI cable is moved at any time before the lock is closed repeat the process Contact Surface starting at step 1. To SLA-HDMI- SDI IN 1750-OEM Figure 47: HDMI Cable Connections © SightLine Applications, LLC...
  • Page 46: Sla-Ffc-Hdmi

    Appendix - Standard Connector #9 Connector J2: HDMI Type A Port uses the standard pinout defined in Appendix - Standard Connector The connector part number is different, but the pinout is the same (see the 3000-HDMI Connector Summary table). © SightLine Applications, LLC...
  • Page 47: Sla-Hdmi-Sdi

    Molex 2POS Housing, 51021-0200 Molex 734151631 SDI/HD-SDI/3G-SDI Output MCX Cable  SIGHTLINE INTERNAL USE ONLY. The SLA-HDMI-SDI serial port on connector J2 is at 3.3V TTL levels. When connecting to a SightLine OEM board use SLA-CAB-0301. © SightLine Applications, LLC...
  • Page 48 HDMI_TMDS_CLK_C_P HDMI_TMDS_CLK_C_N HDMI_TMDS_TX0_C_N HDMI_TMDS_TX0_C_P HDMI_TMDS_TX1_C_P HDMI_TMDS_TX1_C_N HDMI_TMDS_TX2_C_N HDMI_TMDS_TX2_C_P Connector J2: Serial Port SIGHTLINE INTERNAL USE ONLY Connector J3: Power Connector Description Description Typical 12VDC (see voltage specifications for min/max. Ground Connector J4: HDSDI Output 75 Ohms, MCX vertical jack receptacle coax connector.
  • Page 49: Questions And Additional Support

     SIGHTLINE INTERNAL USE ONLY. The SLA- HDMI-SDI interface uses a standard serial port operating at 57.6kBps (8, n, 1). Normally this serial port would be jumpered from a SightLine OEM board. 9 Questions and Additional Support For questions and additional support, please contact SightLine Support.
  • Page 50: Appendix - Standard Connector Pinouts

    Ground Ground Ground VINA_HSYNC Ground VIN_D7 VIN_D6 VINA_VSYNC VIN_D5 VIN_D4 VIN_D3 VIN_D2 VIN_D1 VIN_D0 Ground Ground Ground P3P3V Ground Ground P3P3V Ground VINR Ground VIN_D15 Ground VIN_D14 VINR VIN_D13 VIN_D12 VINR VIN_D11 VIN_D10 VINR VIN_D9 Ground © SightLine Applications, LLC...
  • Page 51 PWR_IN SD0_CLK TXPB HDMA_SDA Ground SD0_CD/DAT3 Ground PWR_IN SD0_DAT0 TXNB Ground Ground SD0_CMD P3P3V PWR_IN SD0_DAT1 Ground P3P3V Ground Ground Ground PWR_IN Ground HDMICLK+ Ground HDMID1+ VIDEOOUT0 PWR_IN HDMICLK- VIDEOOUT1 Ground HDMID1- AGND PWR_IN HDMID0+ AGND © SightLine Applications, LLC...
  • Page 52 • See the SLA-HDMI-SDI section for HDMI_C_HPD HDMI_TMDS_CLK_C_P details on the HDMI to HDSDI HDMI_C_DATA HDMI_TMDS_TX2_C_N converter compatible with this HDMI_C_CLK HDMI_TMDS_TX0_C_N HDMI_TMDS_TX2_C_P HDMI output. HDMI_C_CEC HDMI_TMDS_TX0_C_P • FFC ribbon cable and HDMI connectors: ChenYang Elec. © SightLine Applications, LLC...

Table of Contents