Method to change shield
Installing blade (option)
 Wear heavy duty gloves when working with the trimmer blade.
 When replacing the trimmer blade during a trimming task, ensure that the unit is switched off and that the blades
have stopped.
 Do not attempt to fit the trimmer blade with one hand or without using the socket spanner. Fit the trimmer blade ac-
curately using the supplied socket spanner and tighten firmly in position.
 Do not use any tools other than the provided socket spanner to tighten the blade; a pneumatic or electric tool may
tighten the blade more than necessary and cause the nut or the output shaft to break.
 If worn nut and cup for blade are used, there is a danger of blade getting loose. Replace them with new one.
Failure to do so could lead to an injury or serious accident.

Maintenance and care

 There are two types of shields: namely the one used exclu-
sively for nylon line cutting head and the other one used exclu-
sively for metal blade. When metal blade is used, use the
shield for metal blade.
1.
Fully loosen the bolt (A) on the right side of the bracket (B)
to slide the shield. The bolt itself cannot be removed from the
bracket.
2.
Pushing the button (C), slide the shield (D) to the left and re-
move it.
3.
Put shield of other type (E) into groove and slide it to the right
until it stops. Be sure to tighten the bolt.
WARNING
1.
Inspect blades (A) before installation. Check for sharpness.
Dull blades increase the risk of blade kickback reactions.
Small cracks can develop into fractures resulting in a piece
of blade flying off during operation. Discard cracked blades
no matter how small the crack.
2.
Insert locking tool (B) into a hole located on the right side of
angle transmission while forcing retainer spring to the left
side.
3.
Insert locking tool further into blade retainer fixing slot (C) to
fix output shaft.
4.
Using the socket wrench, remove the nut (D), cup (E), and
lower blade retainer (F).
5.
Securely tighten the blade, lower blade retainer, cup, and nut
by hand.
 Fix output shaft securely using locking tool in order to
prevent it form rotating when blade is mounted. Other-
wise, the blade fastening nut will not be tightened suffi-
ciently.
6.
Tighten the nut (turn anticlockwise) using a socket wrench.
Never fasten while applying your weight. Otherwise the
23