FA U LT
The lights on, but the fan
does not work
The lights and fan
do not work
Serious vibration of the unit
The extraction performance
is not good
If the above table has not solved the problem please contact Caple Service by phone on
0117 938 7420 or by email service@caple.co.uk
18
Instruction manual CGC611 CGC711 CGC911
C A U S E
The fan blade is jammed.
The motor is damaged.
A blown fuse.
The power cord is loose.
The fan blade is damaged.
The fan motor is not fixed tightly.
The unit is not hung correctly on the
bracket.
The filter requires cleaning.
Switch off the unit and contact
Caple Service. To be repaired by qualified
service personnel only.
Replace the fuse.
Plug in to the power supply again.
Switch off the unit and contact
Caple Service. To be repaired by qualified
service personnel only.
Switch off the unit and contact
Caple Service. To be repaired by qualified
service personnel only.
Take down the unit and check whether the
bracket is in the correct location.
Clean the grease filter as directed in the
'Care and maintenance' section. Replace the
charcoal filter (if in recirculation mode).