Troubleshooting
If problems occur while operating this device, verify
that all operating instructions have been adhered to
and then carry out the following troubleshooting
procedures:
Problem
Low laser power
Changed laser spot
No laser beam
Scan head does not steer laser
beam in one or both directions
If the problems persist, please send the scan head to
customer
service.
®
hurrySCAN
10, digital, 1064 nm, f = 254 mm
Rev. 2.6 e
8 Troubleshooting
Possible Cause
Dirty objective
Altered controller software
parameters
Dirty or damaged mirror
Dirty or damaged objective
Dirty or damaged mirror
Laser out of adjustment
Problem with the laser
Problem with the laser controller
Laser beam path blocked or shutter
closed
Problem with the scan head
controller
Remedy
Clean as described in
"Routine
Maintenance of the Optical
Surfaces" on page 31
Check input parameters
Check mirrors. If they are
contaminated, call SCANLAB for
guidance. Return damaged scan
head mirrors for repair.
Clean as described in
"Routine
Maintenance of the Optical
Surfaces" on page 31
Check mirrors. If they are
contaminated, call SCANLAB for
guidance. Return damaged scan
head mirrors for repair.
Adjust laser
Check laser and electrical
connections
®
If the RTC
board is used, check all
electrical connections and the
power supply
Check laser beam path
Check power and data cables.
Check software commands.