SPARK PLUG INSPECTION:
SPARK PLUG INSPECTION:
1. Remove the cap from the spark plug.
2. Remove the spark plug by means of a corresponding spanner.
3. Examine the spark plug.
If it is shattered – it is necessary to replace it. Recommended replacement spark
plugs – A5RTC.
4. Measure the gap. It has to be within range 0.6 – 0.7 mm.
5. Place the spark plug in its place by means of a spark plug spanner.
6. Replace the spark plug cap.
The engine and muffler will be very hot after the engine has been run. Avoid touching the engine and muffler while
they are still hot with any part of your body or clothing during inspection or repair.
1. Remove the screws, and then pull outward on the areas of the cover.
2. Loosen the bolt and remove the muffler cap, the muffler screen and spark arrester.
3. Clean the carbon deposits on the muffler screen and spark arrester using a wire brush.
4. Check the muffler screen and spark arrester. Replace them if damaged.
5. Replace the flame arrester.
6. Replace the screen and cover of the damper.
7. Replace the cover and tighten the screws.
IMPORTANT!
ATTENTION - DANGER!
1. Remove the fuel tank cap and filter.
2. Clean the filter with gasoline.
3. Wipe the filter and install it.
4. Install the fuel tank cap.
Be sure the fuel tank cap is tightened securely.
The generator must be stored in a dry, well-ventilated area that is free from dust. Keep away from children and
animals.
IMPORTANT!
GENERATOR LONG-TERM STORAGE
GENERATOR LONG-TERM STORAGE
If the generator will not be used for a long time, it is recommended to:
- Drain the fuel into the tank.
- Drain the motor oil.
MUFFLER SCREEN AND SPARK ARRESTER
TECHNICAL MAINTENANCE
Tip: Align the spark arrester projection with the hole in the
muffler pipe.
FUEL TANK FILTER TECHNICAL MAINTENANCE
Never use the gasoline while smoking or in the vicinity of an open
flame.
Generator should always remain ready for operation. Therefore
in case of device malfunctions, they are to be repaired before
dismounting the generator for storage.