2c
ENG - When installing Peerless ceiling mounts on a concrete ceiling, the ceiling must be at least 8" thick with a
minimum compressive strength of 2000 psi. Never attach concrete expansion anchors to concrete covered with
plaster, drywall, or other finishing material.
2c-1
ENG
Mark mounting holes.
2c-2
ENG
Drill mounting holes into supporting surface (2.5" (64 mm)
minimum depth required).
WARNING
A
9
ARROW ON TOP OF
PROJECTOR MOUNT
ASSMEBLY INDICATES
FRONT OF MOUNT.
5/16"
(8mm)
2015-06-17
2.5"
(64mm)
5/16"
(8mm)
#:056-9083-1