5-5-3. Method of Starting and Finishing
(1) Starting the E-Mount Lens Adjustment
*
Make sure to disconnect the AC adaptor after finishing the adjustment
(including the case when stops due to an error).
*
SeusEX will start when the E-Mount Lens Adjustment is started.
Procedure of Starting
1. Set the Shooting Mode of the camera to the P mode (Program
Auto), then turn the power on.
2. Start the E-Mount Lens Adjustment.
3. The camera selection window opens, and select "ILCE-5000"
or "ILCE-6300".
Note: Select "ILCE-6300" to perform the focus shift adjustment,
"ILCE-5000" to do other items.
4. Click the [Connect] button and check that the connection status
becomes "Connect".
[].[].[].[]
(2) Finishing the E-Mount Lens Adjustment
Procedure of Finishing
1. Click the [Disconnect] button and check that the connection
status becomes "Disconnect".
[].[].[].[]
2. Click the [] button on the upper right of the main window to
finish the E-Mount Lens Adjustment.
3. Turn off the power of camera.
4. Disconnect the AC adaptor.
5-5-4. Adjustment Method of Each Item
(1) Lens Device (S)
• Adjust and inspection the focusing ring.
Subject
Operation on Lens side
Type of the camera
Shooting Mode of the camera P mode (Program Auto)
Adjusting Method
1. Click the [Lens Device (S)] button in the Adjustment and Inspec-
tion.
2. "Rotate Ring START" is displayed, press the ENTER key.
3. Rotate the focusing ring more than one rotate.
Focusing ring
4. "Rotate Ring STOP" is displayed, press the ENTER key.
5. "MF ROTATION START" is displayed, press the ENTER key.
6. Rotate the focusing ring more than one rotate.
Focusing ring
5-24
SEL24105G
Not required
• Focusing ring
ILCE-5000
– Continued on next page –