6. Start the lens adjustment program "BLG-TestProgramV[][][].exe".
7. When [Open] is clicked and communication between personal computer and B-L Control Box is connected, the button name changes to
[Close] and the [Power] button is made active.
8. Click [Power] to supply power to the lens to be tested.
At this time, confirm that both of the two LEDs on the B-L Control Box are light.
(If either or none of them does not light, there is a problem.)
Power switch
B-L Control Box
Note 1: Before detaching the lens after power is supplied, be sure to
click [Power] again and confi rm that the two LEDs go out.
9. Select "Center Hold" from the steady shot selection menu, and click [Steady Shot].
Steady Shot setting: Center Hold
LEDs for power supply check
5-8
SEL24105G
– Continued on next page –