Description of the device

4.6 Reset button

Note
Primary user (radar) on all enabled channels
If the device detects a competing radar signal on all enabled channels of the WLAN
interfaces, the F LED is lit and R1/R2 flash. No data traffic is then possible for the next
30 minutes. After this time, the device runs the scan again and checks whether a primary
user still exists. If no primary user is detected, data traffic is possible again.
The wait time of 30 minutes is necessary due to legal requirements and cannot be
shortened even by restarting the device.
4.6
Reset button
Position
NOTICE
Loss of the degree of protection
When the cover is not mounted correctly, the device loses its degree of protection.
The Reset button is located behind the screw-down cover on the underside of the
housing, see Device description (Page 21).
Functions
The reset button has the following functions:
• Restart of the device
To restart the device, press the Reset button briefly.
Note
If you make changes to the configuration and restart immediately afterwards with the
reset button, the changes may be lost. If you restart the device using the WBM (menu
command "System > Restart") or using the CLI (command "restart" in the Privileged
EXEC Modus), the configuration changes are always retained.
32
SCALANCE W788-x / W748-1
Operating Instructions, 03/2022, A5E03678333-17

Advertisement

Table of Contents
loading