Siemens SIMATIC NET SCALANCE W788-x Operating Instructions Manual page 31

Table of Contents

Advertisement

LED
F
P1
R1
R2
1) Not for SCALANCE W748-1 M12, SCALANCE W788-2 M12 and SCALANCE W788-2 M12 EEC
SCALANCE W788-x / W748-1
Operating Instructions, 03/2022, A5E03678333-17
Color
Meaning
Access point mode:
Flashing yellow
With DFS (802.11h), the channel is scanned for one minute for
competing radar signals before the channel can be used for data
traffic.
Interval:
100 ms on /
100 ms off
Off
No fault/error.
Red
The device is starting up or an error has occurred.
Flashing red
The bootloader waits in this state for a new firmware file that you can
download by TFTP.
Interval:
500 ms
on / 500 ms off
Flashing red
Firmware on PLUG:
The device is performing a firmware update or downgrade.
Interval:
2000 ms
on / 200 ms off
Red
A competing radar signal was found on all enabled channels.
Simultaneous
R1/R2 yellow
flashing
Flashing yellow
The port LEDs flash for detection of device location.
The "LED flash" function is
Either with SINEC PNI
Or via the WBM page "Discovery and Set via DCP"
Description of the device
4.5 LED display