Technical Data; Voltage Versions And Electrical Data; Connection For Equipotential Bonding; Steam Connection - Miele PW 6241 D Installations Plan

Steam-heated commercial washing machine
Hide thumbs Also See for PW 6241 D:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Voltage versions and electrical data

Supply voltage
Frequency
Power rating
Fuse rating (on site)
Connection cable, min. cross-section
Cable gland
Supply voltage
Frequency
Power rating
Fuse rating (on site)
Connection cable, min. cross-section
Cable gland
Miele recommends connecting the machine via a wall socket with an all-pole means of deactivation and interlock in accordance with
IEC 60309 and IEC 60947 so that electrical safety checks can be carried out easily.
For hard-wired machines, an isolator in accordance with IEC 60947 must be installed.
The wall socket or isolator must remain accessible at all times once the machine has been installed.
To increase safety, Miele recommends installation of a residual current device (RCD). Only use residual current devices that are sensit-
ive to universal current (type B).

Connection for equipotential bonding

Connection with male thread (machine)
Size of washers and nuts
An equipotential bond with good contact connection must always be provided in accordance with all national and local regulations.

Steam connection

Indirect steam heating
Steam overpressure
Boiling point
Heater rating (peak capacity)
Mass flow (peak capacity)
Threaded union (on site)
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.
Direct steam heating
Steam overpressure (high pressure)
Boiling point (high pressure)
Heater rating (peak capacity high pressure)
Mass flow (peak capacity high pressure)
Steam overpressure (low pressure)
Boiling point (low pressure)
Heater rating (peak capacity low pressure)
Heater rating (peak capacity low pressure)
Threaded union (on site)
Steam solenoid valve, dirt filter and steam shut-off valve must be installed by the customer on site. Follow the installation instructions
for steam-heated machines.
en - Technical data
Standard:
3N AC 380-415V
50 Hz
4,3 kW
3 x 16 A
4 x 1,5 mm²
M16 x 1,5 mm
10 mm x 30 mm (3/8" x 1 3/16")
Convertible to:
3N AC 380-415V
60 Hz
4,3 kW
3 x 16 A
4 x 1,5 mm²
M16 x 1,5 mm
3 AC 400V
60 Hz
4,3 kW
3 x 16 A
4 x 1,5 mm²
M16 x 1,5 mm
M 10
400–1000 kPa
152–184 °C
50 kW
84 kg/h
½" female thread
≤ 400 kPa
≤ 152 °C
86 kW
140 kg/h
≤ 50 kPa
≤ 120 °C
29 kW
45 kg/h
¾" female thread
17