Landing Characteristics Settings; Direction Switch Landing Characteristics Settings - Panasonic AW-PH360N Operating Instructions Manual

Indoor pan/tilt head
Hide thumbs Also See for AW-PH360N:
Table of Contents

Advertisement

Installation
$ Controller selection switch / installation direction switch /

landing characteristics settings

The following switches are set when determining controller selections, stand alone
settings and landing characteristics settings.
(RP501 / suspended installation / soft landing are the default settings.)
1. Remove the four head cover screws, and remove the cover slowly. (Take care not to
disturb the tally LED lamp wiring connections when removing the cover.)
2. Set the SW1, SW2 and SW4 switches on the front printed circuit board as follows.
For AW-RP301/AW-RP305/AW-RP501/AW-RP505/AW-RP400:
Set SW1 switch to its right-side position (RP501). (Factory setting)
For AW-RP605A:
Set SW1 switch to its left-side position (RP605).
For suspended installation:
Set SW2 to its left-side position (HANGING). (Factory setting)
For stand-alone installation:
Set SW2 to its right-side position (DESKTOP).
For a soft landing:
Set SW4 switch No.4 to its top position (ON). (Factory setting)
For a precise landing:
Set SW4 switch No.4 to its bottom position (OFF).
3. Upon completion of the settings, return the head cover to its original position, and
secure it with the screws (while taking care not to pinch the wires).
<Notes>
OBefore setting the switches, make absolutely sure that the power of the AC adapter
which is to be connected to the pan/tilt head is set to OFF.
OThe controller selection and landing characteristics are not changed simply by selecting
the switch positions. They are changed only after the power is turned off and back on
again after the switches have been set.
RP605
RP501
(The installation work must be performed by your dealer without fail.)
- 10 -
RS-422
RS-232C
Do not change the setting of this
switch — use it at the RS-422
position.
Suspension
Stand-alone

Advertisement

Table of Contents
loading