TSI Instruments AEROTRAK 9310 Quick Start Manual

TSI Instruments AEROTRAK 9310 Quick Start Manual

Portable airborne particle counters
Hide thumbs Also See for AEROTRAK 9310:

Advertisement

Quick Links

Q
S
UICK
TART
A
T
Model
ERO
RAK
9310/9350/9510/9550
Portable Airborne Particle Counters
Thank you for purchasing a TSI A
Portable Airborne Particle Counter (particle
counter). This guide will help you quickly begin
using your particle counter.
More detailed information is in the manual located
on the included TrakPro Lite CD. Please refer to
the manual if you have questions on the operation
of your new particle counter.

Safety

This section gives instructions to promote safe and
proper handling of the A
Airborne Particle Counters.
I M P O R T A N T
There are no user-serviceable parts inside the
instrument. Refer all repair and maintenance to a
qualified factory-authorized technician. All maintenance
and repair information in this manual is included for use
by a qualified factory-authorized technician.
L A S E R S A F E T Y
The A
T
Portable Airborne Particle Counter is a
ERO
RAK
Class I laser-based instrument. During normal operation,
you will not be exposed to laser radiation. However,
precaution should be taken to avoid exposure to
hazardous radiation in the form of intense, focused,
visible light. Exposure to this light may cause blindness.
DO NOT remove any parts from the particle counter
unless you are specifically told to do so in this manual.
DO NOT remove the housing or covers. There are no
user-serviceable components inside the housing.
G
UIDE
T
ERO
RAK
T
Portable
ERO
RAK
P o r t a b l e P a r t i c l e C o u n t e r s
The use of controls, adjustments, or
procedures other than those specified in
this manual may result in exposure to
hazardous optical radiation.
W A R N I N G
The battery supplied by TSI (700028) has built in
protection against explosion and fire hazard. Do not use
a substitute. Do not use non-rechargeable batteries in
this instrument. Fire, explosions, or other hazards
may result.

Labels

Advisory labels and identification labels are
attached to the outside of the particle counter
housing and to the optics housing on the inside of
the instrument.
Serial Number
Label (back
panel)
Laser Radiation
Label (internal)
VISIBLE LASER RADIATION WHEN
WARNING: NO USER SERVICABLE
PARTS INSIDE. REFER SERVICING
TO QUALIFIED PERSONNEL
European symbol
for non-
disposable item.
Item must be
recycled.
DANGER!
OPEN. AVOID DIRECT
EXPOSURE TO BEAM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AEROTRAK 9310 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for TSI Instruments AEROTRAK 9310

  • Page 1 P o r t a b l e P a r t i c l e C o u n t e r s UICK TART UIDE Model ™ 9310/9350/9510/9550 Portable Airborne Particle Counters The use of controls, adjustments, or ™...
  • Page 2 Unpacking Item Part/Model Reference Picture Description 1. Carefully unpack the particle counter from the HEPA zero 700015 shipping container and verify that all the items filter assembly listed in the following table are present. 2. Contact TSI immediately if items are missing or ™...
  • Page 3 Running the Particle Counter 9. The portable particle counters are controlled using a touch screen display. Use the plastic stylus or your finger tip. DO NOT use sharp objects (such as a pen point) that may damage the screen overlay. 10.
  • Page 4 Set up Time/Date Collecting Samples 17. From the Main tab, select the Setup tab then 22. Press to start a sample. This turns on the Device Setup, then select Date and Time. pump and the particle counter runs for 10 18.