Completing the Installation
__ 1. Power on your PC or workstation that is your system unit console.
__ 2. Is your system unit an AS/400e 270 or 820?
__ 3. Look at the Function/Data display on the control panel.
__ 4. Does 01 B N V=S appear in the Function/Data display?
__ 5. Look at the Function/Data display on the control panel.
__ 6. Does 01 B V=S appear in the Function/Data display?
8
AS/400e 270 or 820: Upgrading the System Unit from Operations Console to Twinaxial Console (5540)
270
820
↓
Go to step 5.
No
Yes
↓
Do the following:
__ a. Press the Increment/Decrement push button until 02 appears
in the Function/Data display.
__ b. Press the Enter push button on the control panel.
__ c. Press the Increment/Decrement push button until B appears
in the Function/Data display.
__ d. Press the Enter push button on the control panel.
__ e. Press the Increment/Decrement push button until M appears
in the Function/Data display.
__ f. Press the Enter push button on the control panel.
__ g. Press the Increment/Decrement push button until S appears
in the Function/Data display.
__ h. Press the Enter push button on the control panel.
__ i. Press the Increment/Decrement push button until 01 appears
in the Function/Data display.
__ j. Press the Enter push button on the control panel.
01 B M S should appear in the Function/Data display. If it
does not, repeat steps 4a through 4i.
__ k. Go to step 7 on page 9.
Go to step 7 on page 9.
Yes
No
↓
Do the following:
__ a. Press the Mode Select button until the Manual mode
indicator (a small hand) lights up.
__ b. Press the Increment/Decrement push button until 02 appears
in the Function/Data display.
__ c. Press the Enter push button on the control panel.
__ d. Press the Increment/Decrement push button until B appears
in the Function/Data display.
__ e. Press the Enter push button on the control panel.
__ f. Press the Increment/Decrement push button until S appears
in the Function/Data display
__ g. Press the Enter push button on the control panel.
__ h. Press the Increment/Decrement push button until 01 appears
in the Function/Data display.