Dickey-John MINI GAC Operator's Manual

Dickey-John MINI GAC Operator's Manual

Grain moisture analyzer
Hide thumbs Also See for MINI GAC:

Advertisement

MINI GAC
MINI GAC
GRAIN MOISTURE ANALYZER
®
S I N C E 1 9 6 6
AND
®
PLUS
®

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MINI GAC and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Dickey-John MINI GAC

  • Page 1 ® S I N C E 1 9 6 6 MINI GAC ® MINI GAC PLUS ® GRAIN MOISTURE ANALYZER...
  • Page 2: Table Of Contents

    History ................ 22 Grain Calibrations ............23 Accuracy ................25 Condensing Samples (Corn Drying) ......25 High Moisture Grains ..........25 Improving Grain Test Results ........26 Error Codes ............... 27 Diagnostics ............... 35 Information ..............35 mini GAC® 11001-1464A-201701 Rev B...
  • Page 3 OPERATOR’S MANUAL / II mini GAC® 11001-1464A-201701 Rev B...
  • Page 4: Introduction

    (mini GAC plus only) of the sample. The unit operates using four function keys coupled with a menu-driven operating system.
  • Page 5: Specifications

    STORAGE The Loader should be turned upside down and placed inside the unit for storage. Figure 2 Loader/Unit Storage Loader mini GAC Unit ® 2 / INTRODUCTION mini GAC 11001-1464A-201701 Rev B...
  • Page 6: Battery

    Home menu. UP AND DOWN ARROW BUTTONS The Up and Down Arrow buttons are used to scroll through the DOWN items on the menu. (Figure 3) illustrates the Switchpad area. ® INTRODUCTION / 3 mini GAC 11001-1464A-201701 Rev B...
  • Page 7: Cursor Selection Tool

    Keys Home Enter Use care when handling the mini GAC unit. Any misuse of the unit, such as tossing, dropping, or throwing, can potentially damage the internal measuring device. The unit should be stored in the case when not in use.
  • Page 8: Quick Start Guide

    7. When secured, pull Loader slide out to dispense grain into the unit. 8. Remove the Loader and use the level edge to strike any excess grain from the unit. 9. Press Enter to begin the test. ® QUICK START GUIDE / 5 mini GAC 11001-1464A-201701 Rev B...
  • Page 9 1. Scoop 2. Pull Slide 3. Strike Grain Use care when handling the mini GAC unit. Any misuse of the unit, such as tossing, dropping, or throwing, can potentially damage the internal measuring device. The unit should be stored in the case when not in use.
  • Page 10: Settings

    OPERATOR’S MANUAL SETTINGS The mini GAC can be customized to user preferences by changing the following control settings from the Setup menu: • Languages • Results - test weight and temperature (mini GAC plus) • Display • Average buffer size •...
  • Page 11 On/Off/Home button to escape and retain averages and history. Figure 6 Modifying Language Settings Corn History Setup Setup Language Results Language English US English UK French Italian Averages and History will be cleared. Continue? ® 8 / SETTINGS mini GAC 11001-1464A-201701 Rev B...
  • Page 12: Results

    OPERATOR’S MANUAL RESULTS (MINI GAC PLUS ONLY) The Results menu is only available on the mini GAC plus testers. The Results menu controls the appearance of test weight and product temperature results for each measurement on the Test Results menu. The default is set to Show results.
  • Page 13: Average

    1. From the Home menu, press the Down Arrow button and scroll to Setup and press Enter. 2. Scroll and press Enter to select the Backlight menu. 3. Press the Up or Down Arrow button to turn backlighting on or off. ® 10 / SETTINGS mini GAC 11001-1464A-201701 Rev B...
  • Page 14: Contrast

    4. Press the Enter button to save the changed setting or the On/Off/Home button to escape and retain the previous setting. Figure 10 Modifying Display Contrast Corn History Setup Setup Backlight Contrast Contrast ® SETTINGS / 11 mini GAC 11001-1464A-201701 Rev B...
  • Page 15: Units

    90 seconds. Power off durations available: • 10 seconds • 15 seconds • 20 seconds • 30 seconds • 45 seconds • 60 seconds • 90 seconds • Infinite (manual shut off) ® 12 / SETTINGS mini GAC 11001-1464A-201701 Rev B...
  • Page 16 4. Press the Enter button to save the changed setting or the On/Off/Home button to escape and retain the previous setting. Figure 12 Modifying the Power Down Settings Corn History Setup Setup Units Power Power Off After Seconds ® SETTINGS / 13 mini GAC 11001-1464A-201701 Rev B...
  • Page 17 +33 1 41 19 21 80 europe@dickey-john.com 5200 Dickey-john Road 217-438-3371 Auburn, IL 62615 217-438-6012 fax www.dickey-john.com ©2017 DICKEY-john ® S I N C E 1 9 6 6 DICKEY-john, the DICKEY-john Logo and GAC are registered trademarks of DICKEY-john. 11001-1464A-201701 Rev B...