6 Technical data

6 Technical data

6.1 Medium

Working medium:
Dust content:
Pressure dew point:
Oil content:

6.2 Temperature

Ambient temperature:
Storage temperature:

6.3 Pressure

Operating pressure:
Flow rate:
Air consumption:

6.4 Product compliance

EMC Directive:
Radio Equipment Direct-
ive (RED):
GEMÜ 1441 cPos-X
Compressed air and inert gases
Class 4, max. particle size 15 μm, max. particle density 5 mg/m³
Class 4 (10 K below the ambient temperature)
Class 4, max. oil concentration 25 mg/m³
Quality classes to DIN ISO 8573-1
-10 — 60 °C
-10 — 60 °C
1,5 — 7 bar
The applied pressure must not exceed the maximum control pressure of the process valve.
115 Nl/min (@ 25 °C; 6->5 bar)
≤ 0.05 Nl/min (when idle)
2014/30/EU
Technical standards used:
Interference emission:
Interference resistance:
Class:
Group:
2014/53/EU
Technical standards used:
Standard regarding the use
of radio frequencies:
Electromagnetic compatibil-
ity (EMC) for radio devices
and services:
Electrical safety:
DIN EN 61000-6-3:2007/A1:2011/AC:2012
DIN EN 61326-1 (industry) (07/2013)
EN IEC 61000-6-1:2019
EN 61326-1:2013 (industry)
B
1
EN 300 328 V2.2.2 (2019-07)
EN 301 489-1 V2.2.3 (2019-11)
EN 301 489-17 V3.2.4 (2020-09)
EN 61010-1:2010 + A1:2019 +
A1:2019/AC:2019
8 / 33
www.gemu-group.com