6. Technical specifications
M5T HV (400V)
CAPACITY*
INPUT
Low Line Loss
Low Line
Voltage
Comeback
Range
High Line Loss
High Line
Comeback
Frequency Range
Phase
Power Factor
OUTPUT
Phase
Output voltage
AC Voltage Regulation
Frequency Range
(Synchronized Range)
Frequency Range (Batt.
Mode)
AC mode
Overload
Battery mode
Current Crest Ratio
Harmonic Distortion
Line
Batt
ery
Transfer
Inverter
Time
Bypass
Inverter
ECO
EFFICIENCY
AC mode
ECO mode
Battery Mode
BATTERY
Type
Numbers
Recharge Time
Standard
Charging
Model
Current (max)
Charging
Voltage
Type
Numbers
Long-run
Charging
Model
Current(max.)
Charging
Voltage
PHYSICAL
Dimension, D X
W X H (mm)
Standard
Model
Net Weight
(kgs)
Dimension, D X
Long-run
W X H mm
Model
Net Weight
(kgs)***
ENVIRONMENT
Operation Temperature
Operation Humidity
Operation Altitude**
INFOSEC UPS SYSTEM – 15, rue du Moulin – 44880 Sautron, France – www.infosec-ups.com
141
Hotline : +33 (0)2 40 76 15 82 – Fax : +33(0)2 40 94 29 51 – hotline@infosec.fr – 02 22 AA 59 203 08
M5T 10K
M5T 15K
(WOB)
(WOB)
10KVA / 10KW 15KVA / 15KW 20KVA / 20KW 30KVA / 30KW 40KVA / 40KW 60KVA / 60KW
110 VAC(Ph-N) ± 3 % at 50% Load; 176 VAC(Ph-N) ± 3 % at 100% Load
300 VAC(L-N) ± 3 % at 50% Load; 276 VAC(L-N) ± 3 % at 100% Load
3 x 360*/380/400/415 VAC (3Ph+N) or
208*/220/230/240 VAC (Ph-N)
100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;>150% : immediately
100%~110%: 60min; 110%~125%: 10min; 125%~150%:1min;>150% : immediately
≦ 2 % @ 100% Linear Load; ≦ 5 % @ 100% Non-linear Load
0 ms (When phase lock fails, <4ms interruption occurs from inverter to bypass)
12 V / 9 Ah
12 V / 7 Ah
(10+10)pcs
(16+16)pcs
9 hours recover to 90% capacity
1.0 A ± 10% (Recommended) 1.0~12.0A (Adjustable)
+/-136.5 VDC
± 1%
20
+/-136.5 VDC
± 1%
627 x 250 x 826
105
125
627 x 250 x 826
41
45
0 ~ 40°C (the battery life will down when > 25°C)
M5T 20K
M5T 30K
(WOB)
(WOB)
Low Line Loss Voltage + 10V
High Line Loss Voltage - 10V
46Hz ~ 54 Hz @ 50Hz system
56Hz ~ 64 Hz @ 60Hz system
3 Phase with Neutral
≧ 0.99 at 100% Load
3 Phase with Neutral
3 x 360*/380/400/415 VAC (3Ph+N)
± 1%
46Hz ~ 54 Hz @ 50Hz system;
56Hz ~ 64 Hz @ 60Hz system
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
3:1 max
0 ms
<10 ms
95.5%
98.5%
94.5%
12 V / 9 Ah
12 V / 7 Ah
(16+16)pcs x 2 strings
+/-218 VDC ± 1%
Depending on applications
32 ~ 40 (adjustable)
1.0~12.0A ±10% (Adjustable)
+/- 13.65 VDC * N ± 1% (N = 16~20)
815 x 300 x 1000
125
213
45
78
<95 % and non-condensing
<1000m**
M5T 40K
M5T 60K
(WOB)
S
12 V / 9 Ah
-
1~18A
(ajustable)
-
245
815 x 300 x 1000
80
87