4.
Monitoring Your Server
To check the operating status of your server (taking S19 Pro Hydro 162T as an example):
1.
Click the status below to check the server status.
Note: The frequency of S19 Pro Hydro server is fixed with the value 550 MHz. Firmware will stop running
when the Temp (PCB) reaches to 80℃ or the water temperature is either greater than 65℃ or lower than
20℃,there will be an error message "Fatal Error: Temperature is too high!" shown on the Bottom of the
Kernel log page.
2.
Monitor your server according to the descriptions in the following table:
Option
ASIC#
Frequency
GH/S(RT)
Temp(PCB)
Temp(Chip)
ASIC status
Number of chips detected in the chain.
ASIC frequency setting.
Hash rate of each hash board ( GH/s)
Temperature of each hash board (°C).(Applied only to server with fixed frequency)
Temperature of the chips on each hash board (°C).
One of the following statuses will appear:
●
O - indicates OK
●
X - indicates error
●
- - indicates dead
- 12 -
S19 Pro Hydro Server Installation Guide
Description
4. Monitoring Your Server
Need help?
Do you have a question about the ANTMINER S19 Pro Hydro Server and is the answer not in the manual?