Monitoring Your Server - BITMAIN ANTMINER S17e Installation Manual

Table of Contents

Advertisement

4.

Monitoring Your server

To check the operating status of your server:
1. Click the status marked below.
Note: The S17e server is with automatic frequency. Firmware will stop running when the Temp
(PCB) reaches to 85℃ or Temp(chips) reaches to 98℃,there will be an error message "Fatal Error:
Temperature is too high!" shown in the bottom of kernel log page.
2. Monitor your server according to the descriptions in the following table:
Option
ASIC#
Number of chips detected in the chain.
Frequency
ASIC frequency setting.
GH/S(RT)
Hash rate of each hash board (GH/s).
Temp(PCB)
Temperature of each hash board (°C). (Applied only to server with fixed frequency).
Temp(Chip)
Temperature of the chips on each hash board (°C).
ASIC status
One of the following statuses will appear:
O - indicates OK
X - indicates error
- - indicates dead
Description
- 11 -
S17e Server Installation Guide
4. Monitoring Your Server