  • Page 1 Instructions for use Hawker ® Perfect Plus ™ Water Less ® ATEX certified batteries...
  • Page 2 Instructions for use Hawker Perfect Plus / Water Less ATEX ENGLISH ® ™ ® Motive power batteries Ex certified increased safety “e” Operation and Instruction Manual Introduction These Hawker ATEX certified batteries are certified for use in areas with risks of explosion due to gas or dust. ®...
  • Page 3 • Pay attention to the operating instructions and keep them close to the battery. • Electrolyte is highly corrosive. • Work on batteries must only be carried out by skilled personnel! • protective glasses wear safety • Batteries and cells are heavy. Ensure secure installation! clothing when working on batteries.
  • Page 4 • if the voltage readings are irregular, also check the S.G. of each cell If significant changes from earlier measurements or differences between the cells or bloc batteries are found, please contact EnerSys Service. • If the discharge time of the battery is not sufficient, check: •...
  • Page 5 measure the specific gravity, the liquid level shows the value on the 7. Discharge scale, which is printed on the float. After reading, the rubber bulb Be sure that all ventilation holes are not sealed or covered. Electrical should be squeezed to return the electrolyte to the cell. connections (e.g.
  • Page 6 Aquamatic water refilling system (optional accessory) 2.1.1. If manual connection is used the battery should only be connected to the filling system once a week. 1. Application 2.1.2 If automatic coupling is used (with a magnetic valve The water refilling system is used to automatically maintain the controlled charging apparatus)
  • Page 7 (without electrolyte circulation). 2. Function In case of faulty parts, contact EnerSys service. Only EnerSys original spare parts may be used, as these are designed for the pump air supply The electrolyte circulation consists of a pipe system fitted in the cells.
  • Page 8 Please refer to the website address for details of your nearest EnerSys office: www.enersys.com © 2022 EnerSys. All rights reserved. Trademarks and logos are the property of EnerSys and its affiliates unless otherwise noted. Subject to revisions without prior notice. E.&O.E.