Connections; Connection Examples - ABB Spot 35 R Original Instructions Manual

Safety light beam
Table of Contents

Advertisement

3

Connections

Electrical connections – Spot
1
2
3
4
Transmitter:
4-pole male M12-connector
1 ) +24 VDC
2 ) Dynamic signal input
3 ) 0 VDC
4 ) Not used
Warning! The information output signal is non-failsafe and must therefore never be used to control a safety
application.

Connection examples

Connection example – Connection of Spot T/R to Vital 1
2TLC172178M0201, rev. D
2011-11-15
Spot T
Receiver:
5-pole male M12-connector
1 ) +24 VDC
2 ) Not used
3 ) 0 VDC
4 ) Dynamic signal output
5 ) Information output
Spot R
2
1
5
3
4
M12 5-pole male seen
from cable side
7
1
2
3
4
5
1
2
5
4
3
M12 5-pole female
seen from cable side